Skip to main content
PRODUCTS | ELECTRICAL BOARDS
ECP 200 EXPERT PULSE

CONTROL PANEL FOR PULSE ELECTRONIC EXPANSION VALVE

    Electrical panel for cold room control with differential magnetothermic circuit breaker and with integrated command of pulse electronic expansion valve 230Vac On/Off and single-phase compressor up to 2HP. This panel can be used also only for the control of the evaporating unit.

      Applications
      • Complete control of single-phase static or ventilated refrigeration systems up to 2 HP, with off-cycle or electrical defrosting and direct or pump-down compressor stop.

      • Thought for systems with evaporator managed by ON/OFF electronic expansion valve at 230 Vac.

      • Utility for managing the single-phase evaporating unit with electronic expansion valve only ON/OFF at 230 Vac.

      Main characteristics
      • Compatible with 22 gases: R404, R134, R22, R407A, R407F, R407H, R410A, R450A, R507, R513A, R744(CO2), R449A, R290, R32, R448A, R452A, R600, R600A, R1270, R1234ze, R23, R717(NH3).
      • Defrost with real time clock.
      • Indipendent and separated functions for alarm relay and TeleNET or Modbus-RTU standard protocol.
      • Control of electronic expansion valve ON/OFF with 230 VAC coil.
      • The integration of the valve control permits its programming and a simplified management with the same display, enabling an immediate start-up of the system.
      • Direct control of compressor, defrosting heaters, evaporator fans and room light with free-voltage outputs.
      • Built-in differential magnetothermic breaker for protection and cut-off of refrigeration unit.
      • Innovative, stylish design. Transparent cover for access to magnetothermic breaker, all with IP 65 protection rating.
      • Auxiliary relay with parameter-configured activation (alarm, temperature set-point, direct control via frontal pushbutton, thermostat-holder demisting element).
      • RS485 for connection to TeleNET industrial supervision network or Modbus-RTU standard protocol.
      • Easy installation and opening thanks to new hinged cover.
      • Simple, flexible programming gives extreme versatility of use.
      • Compressor can be run in pump-down stop mode.
      • Installation times and costs reduced thanks to incorporation of control and protection in a single room-dedicated unit.
      Properties
      Dimension
      ECP 200 EXPERT PULSE
      263 x 180 x 96 mm
      Weight
      ECP 200 EXPERT PULSE
      1,3kg
      Front protection rating
      ECP 200 EXPERT PULSE
      IP 65
      Power supply
      ECP 200 EXPERT PULSE
      230 VAC ±10% 50/60 Hz
      Status indicator
      ECP 200 EXPERT PULSE
      Led + Display
      Load type
      ECP 200 EXPERT PULSE
      Single phase
      Working temperature
      ECP 200 EXPERT PULSE
      -5 ÷ +50 °C
      Storage temperature
      ECP 200 EXPERT PULSE
      -10 ÷ +70°C
      Relative ambient humidity
      ECP 200 EXPERT PULSE
      30% - 90% RH without condensate
      Reading range
      ECP 200 EXPERT PULSE
      -45 ÷ +99°C
      Control
      ECP 200 EXPERT PULSE
      Pego
      Alarm signals
      ECP 200 EXPERT PULSE
      Led + Buzzer
      Defrosting
      ECP 200 EXPERT PULSE
      Electrical (RTC)
      Resolution
      ECP 200 EXPERT PULSE
      0,1 °C
      Compressor functioning mode selection
      ECP 200 EXPERT PULSE
      Pump Down - Thermostat
      Ambient probe
      ECP 200 EXPERT PULSE
      NTC 10 kΩ
      Evaporator probe 1
      ECP 200 EXPERT PULSE
      NTC 10 kΩ
      Suction probe
      ECP 200 EXPERT PULSE
      NTC 10 kΩ
      Evaporation pressure probe
      ECP 200 EXPERT PULSE
      4-20mA / 0-5V RATIO
      Door switch
      ECP 200 EXPERT PULSE
      Present
      High/low pressure switch
      ECP 200 EXPERT PULSE
      Present
      Man in cold-room alarm
      ECP 200 EXPERT PULSE
      Present
      Compressor
      ECP 200 EXPERT PULSE
      1500W (AC3)
      Defrosting heaters 1
      ECP 200 EXPERT PULSE
      3000W (AC1) free voltage contact
      Evaporator fans
      ECP 200 EXPERT PULSE
      500W (AC3) free voultage contact
      Electronic expansion valve
      ECP 200 EXPERT PULSE
      Pulse 230 VAC
      Room light
      ECP 200 EXPERT PULSE
      800W (AC1) free voltage contact
      Alarm/AUX relay
      ECP 200 EXPERT PULSE
      100W free voltage contact
      Supervision
      ECP 200 EXPERT PULSE
      TeleNet / Modbus-RTU
      Dimension
      ECP 200 EXPERT PULSE
      Connection Scheme
      ECP 200 EXPERT PULSE
      Technical Characteristics
      Inputs
      Outputs
      Dimensions and Diagram