Italian - ItalyEnglish (United Kingdom)French (Fr)Español(Spanish Formal International)Deutsch (DE-CH-AT)

.

PRODUCTS
THERMOSTATS
EXPERT NANO SNOW
EXPERT NANO 1LT
EXPERT NANO 3CF
EXPERT NANO 4CK
EXPERT NANO 2ZN
EXPERT NANO MILK
NANO BOX
NANO ADAPTER
MODULAR ELECTRONICS
PEV series
PEV PULSE
PEV STEPPER
PEV P20
PEV S27
NEXUS series
NEXUS P20
NEXUS S27
VISION series
VISION SC 600
VISION THR
VISION 2PLT
200CASVIS03
VISION TOUCH series
VISION TOUCH THR
VISION TOUCH PAN
VISION TOUCH AB
VISION TOUCH WELLNESS
VISION TOUCH
COPL24II
ACCFLTOUCH
400SAUNASENS
PLUS100 series
PLUS100 AB
PLUS100 PAN
PLUS100 THR
PLUS100 2PLT
DIN NANO series
DIN NANO 4CK
DIN NANO 5CK
DIN NANO SC500
DIN CHILLER
DIN NANO FSC
DIN SPM
ELECTRICAL BOARDS
Serie HYPERANGE
HYPERANGE 030 B6 VEH-1 / VEH-2
HYPERANGE 075 / 100 B6 VEH
BASE series
ECP 202 BASE
ECP 300 BASE4 VD
ECP 400/750/1000 BASE4 VD
ECP 1500/2000/2500 BASE4 VDE
ECP 300 BASE4 U VD
ECP 400/750/1000 BASE4 U VD
ECP 7.5/15/19.5 BASE4 U VDE
ECP 25/36 BASE4 U VDE
ECP 16/21 BASE STEPPER U VDE
ECP 30/42 BASE STEPPER U VDE
ECP 1000 2EV U
EXPERT series
ECP 202 EXPERT
ECP 202 EXPERT D7.5
ECP 200 EXPERT 2EV
ECP 200 EXPERT PULSE
ECP 300 EXPERT VD
ECP 300 EXPERT U VD
ECP 300 EXPERT STEPPER U VD
PLUS series
PLUS200 2PLT
PLUS1000 THR
PLUS EXPERT series
PLUSR 200 EXPERT
PLUSR 300 EXPERT VD
PLUSR 300 EXPERT U VD
PLUSR EXPERT DL3
PLUSR EXPERT DL8
PLUS 200 EXPERT THR
PLUS 300 EXPERT U THR
NANO VD > NANO U VD series
NANO 04 VD
NANO 300 VD
NANO 400/750/1000 VD
NANO 7.5 U VD
NANO 15/19,5 U VD
VD > VD CR > APE series
ECP 04 / ECP 04 M
ECP 07/10
ECP 15
ECP 20
ECP 30
ECP 300 VD
ECP 400/750/1000 VD
ECP 300 VD CR
ECP 400/750/1000 VD CR
ECP 1500/2000/2500 VD CR
ECP 1000 2EV U CR
ECP APE 03
SUPERVISION SYSTEM
TELENET WEB
EXPERT GSM
TWM3 T P UR
TWM3 IO
ACCESSORIES
EXPERT GSM
ECP APE 03
MICRO P
CUSTOMIZED PANELS
EXAMPLES
QUOTATION REQUEST
PILOT SYSTEM
HUMIDIFIERS
LIGHTING
EXPERT LED
EXPERT LED LV
EXPERT LED MEAT
EXPERT LED EMERGENCY
APPLICATIONS
COLD ROOMS
HYPERANGE Series
HYPERANGE 030 B6 VEH-1 / VEH-2
HYPERANGE 075 / 100 B6 VEH
ECP 202 EXPERT
ECP 202 EXPERT D7.5
ECP 200 EXPERT 2EV
ECP 200 EXPERT PULSE
ECP 300 EXPERT VD
ECP 202 BASE
ECP 300 BASE4 VD
ECP 400/750/1000 BASE4 VD
ECP 1500/2000/2500 BASE4 VDE
ECP 300 VD
ECP 400/750/1000 VD
ECP 300 VD CR
ECP 400/750/1000 VD CR
ECP 1500/2000/2500 VD CR
NANO 04 VD
NANO 300 VD
NANO 400/750/1000 VD
Micro P
CONDENSING UNITS
ECP 04 / ECP 04 M
ECP 07/10
ECP 15
ECP 20
ECP 30
EVAPORATING UNIT
ECP 300 EXPERT U VD
ECP 300 EXPERT STEPPER U VD
ECP 300 BASE4 U VD
ECP 400/750/1000 BASE4 U VD
ECP 7.5/15/19.5 BASE4 U VDE
ECP 25/36 BASE4 U VDE
ECP 1000 2EV U
NANO 7.5 U VD
NANO 15/19,5 U VD
ECP 16/21 BASE STEPPER U VD
ECP 30/42 BASE STEPPER U VD
DISPLAY WINDOWS AND REFRIGERATION UNITS
EXPERT NANO 1LT
EXPERT NANO 3CF
EXPERT NANO 4CK
NANO ADAPTER
DIN NANO 4CK
DIN NANO 5CK
PEV PULSE
PEV STEPPER
PILOT SYSTEM
PEV P20
PEV S27
NEXUS P20
NEXUS S27
DATALOGGER
PLUSR 200 EXPERT
PLUSR 300 EXPERT VD
PLUSR 300 EXPERT U VD
PLUSR EXPERT DL3
PLUSR EXPERT DL8
SUPERVISION SYSTEM AND ALARMS
TELENET WEB
EXPERT GSM
TWM3 T P UR
TWM3 IO
ECP APE 03
FAN SPEED CONTROLLER
DIN NANO FSC
DIN SPM
COMPRESSOR RACK AND CHILLER
VISION SC 600
DIN NANO SC 500
DIN CHILLER
DOUBLE SAFETY SYSTEM
VISION 2PLT
PLUS100 2PLT
PLUS200 2PLT
SEASONING
PLUS 200 EXPERT THR
PLUS 300 EXPERT U THR
PLUS1000 THR
PLUS100 THR
VISION THR
VISION TOUCH THR
SONEE16F6A21
PAUSE-LEAVENING
PLUS100 PAN
VISION TOUCH PAN
SONEE16F6A21
DEEP FREEZERS
PLUS100 AB
VISION TOUCH AB
WELLNESS
VISION TOUCH WELLNESS
LIGHTING
EXPERT LED
EXPERT LED LV
EXPERT LED MEAT
EXPERT LED EMERGENCY
SPECIAL APPLICATIONS
EXPERT NANO 2ZN
EXPERT NANO MILK
TECHNICAL DOCUMENTATION

......................................................

Follow us:
ECP 200 EXPERT PULSE
Brochure download

CONTROL PANEL FOR PULSE ELECTRONIC EXPANSION VALVE

Electrical panel for cold room control with  differential magnetothermic circuit breaker and with integrated command of pulse electronic expansion valve 230Vac On/Off and single-phase compressor up to 2HP. This panel can be used also only for the control of the evaporating unit.

 

Applications
Complete control of single-phase static or ventilated refrigeration systems up to 2 HP, with off-cycle or electrical defrosting and direct or pump-down compressor stop.
Thought for systems with evaporator managed by ON/OFF electronic expansion valve at 230 Vac.
Utility for managing the single-phase evaporating unit with electronic expansion valve only ON/OFF at 230 Vac.

Main characteristics
Compatible with 22 gases: R404, R134, R22, R407A, R407F, R407H, R410A, R450A, R507, R513A, R744(CO2), R449A, R290, R32, R448A, R452A, R600, R600A, R1270, R1234ze, R23, R717(NH3).
Defrost with real time clock.
Indipendent and separated functions for alarm relay and TeleNET or Modbus-RTU standard protocol.
Control of electronic expansion valve ON/OFF with 230 VAC coil.
The integration of the valve control permits its programming and a simplified management with the same display, enabling an immediate start-up of the system.
Direct control of compressor, defrosting heaters, evaporator fans and room light with free-voltage outputs.
Built-in differential magnetothermic breaker for protection and cut-off of refrigeration unit.
Innovative, stylish design. Transparent cover for access to magnetothermic breaker, all with IP 65 protection rating.
Auxiliary relay with parameter-configured activation (alarm, temperature set-point, direct control via frontal pushbutton, thermostat-holder demisting element).
RS485 for connection to TeleNET industrial supervision network or Modbus-RTU standard protocol.
Easy installation and opening thanks to new hinged cover.
Simple, flexible programming gives extreme versatility of use.
Compressor can be run in pump-down stop mode.
Installation times and costs reduced thanks to incorporation of control and protection in a single room-dedicated unit.

 

TECHNICAL CHARACTERISTICS
ECP 200 EXPERT PULSE
Dimension
263 x 180 x 96 mm
Weigh 2 Kg
Protection rating
IP 65
Power supply
230 VAC ±10% 50/60 Hz
Load type
Single phase
Working temperature
-5 ÷ +50°C
Storage temperature -10 ÷ +70°C
Relative ambient humidity
<90% Rh
Main switch - general protection
2 poles differential magnetothermic 16A
Control
PEGO
Defrosting
Electrical
Component status indicator
Led + Display
Alarm signals
Led + Buzzer
Defrost
PRESENT (RTC)
INPUTS
Ambient probe
NTC 10 KΩ
Evaporator probe
NTC 10 KΩ
Suction probe
NTC 10 KΩ
Evaporation pressure probe
4-20MA / 0-5V RATIO
Door switch
PRESENT
High/low pressure switch
PRESENT
Man in cold room alarm
PRESENT
Compressor work mode selection
Pump down - Thermostat
Outputs
Compressor 1500 W (AC3)
Evaporator fans
500 W (AC3) free voltage contact
Defrosting heater
3000 W (AC1) free voltage contact
Electronic valve
Pulse 230 Vac
Room light
800 W (AC1) free voltage contact
Auxiliary relay or alarm
100 W free voltage contact
Supervision system
TELENET/MODBUS-RTU
DIMENSION
ECP200-EXPERT-PULSE
CONNECTION SCHEME

ECP200-EXPERT-PULSE

(*) = Configurable function

 

DOWNLOAD INSTRUCTION
Instruction manual