Skip to main content
PRODUCTS | ELECTRICAL BOARDS
ECP16/21 BASE STEPPER U VDE

LINE OF ELECTRICAL PANELS, WITH POWER AND CONTROL OF THE STEPPER ELECTRONIC EXPANSION VALVE (STEPPER MOTOR), DEDICATED TO THE MANAGEMENT OF THE THREE-PHASE EVAPORATING UNIT.

LINE OF ELECTRICAL PANELS, WITH POWER AND CONTROL OF THE STEPPER ELECTRONIC EXPANSION VALVE (STEPPER MOTOR), DEDICATED TO THE MANAGEMENT OF THE THREE-PHASE EVAPORATING UNIT.
LINE OF ELECTRICAL PANELS, WITH POWER AND CONTROL OF THE STEPPER ELECTRONIC EXPANSION VALVE (STEPPER MOTOR), DEDICATED TO THE MANAGEMENT OF THE THREE-PHASE EVAPORATING UNIT.

    Line of electrical panels, with power and control of the stepper electronic expansion valve (stepper motor), dedicated to control only the three-phase evaporating unit where units are served by a central refrigerator or remote condenser unit.
    The different power ranges and the various options available allow to choose the panel best suited to your system.

    LINE OF ELECTRICAL PANELS, WITH POWER AND CONTROL OF THE STEPPER ELECTRONIC EXPANSION VALVE (STEPPER MOTOR), DEDICATED TO THE MANAGEMENT OF THE THREE-PHASE EVAPORATING UNIT.
    LINE OF ELECTRICAL PANELS, WITH POWER AND CONTROL OF THE STEPPER ELECTRONIC EXPANSION VALVE (STEPPER MOTOR), DEDICATED TO THE MANAGEMENT OF THE THREE-PHASE EVAPORATING UNIT.
      Applications
      • Control of the evaporating unit, with electrical defrostup to 21 kW.

      • Management of the motorized bipolar expansion valve.

      Main characteristics
      • Driver for the motorized electronic valve integrated in the cold room control.
      • Single display for complete cold room management.
      • Connectable to any type of stepper valve on the market.
      • Including parameters self-configuration table based on the brand and model of the valve.
      • Internal USB port for updates with new refrigerant gases.
      • Enabling for condensing unit, defrost heaters, evaporator fans, solenoid valve, cold room light and presence of all the electrical protections required by regulations.
      • Protection of the loads and of the auxiliary circuit with circuit breakers.
      • Compact, self-extinguishing abs housing with IP65 protection rating and circuit breaker on the front of the panel.
      • Electronic control with large LED display and easy-to-use keyboard.
      • LED system status indicators.
      • RS485 serial port for connection to the TeleNET industrial supervision network or standard Modbus-RTU protocol.
      • Alarm output with voltage-free contact to activate other warning devices such as sirens or telephone dialer.
      Properties
       
      ECP16 BASE STEPPER U VDE
      ECP21 BASE STEPPER U VDE
      Dimension
      ECP16 BASE STEPPER U VDE
      350 x 450 x 160 mm
      ECP21 BASE STEPPER U VDE
      350 x 450 x 160 mm
      Weight
      ECP16 BASE STEPPER U VDE
      9kg
      ECP21 BASE STEPPER U VDE
      10kg
      Front protection rating
      ECP16 BASE STEPPER U VDE
      IP 65
      ECP21 BASE STEPPER U VDE
      IP 65
      Power supply
      ECP16 BASE STEPPER U VDE
      400 VAC ±10% 50/60 Hz
      ECP21 BASE STEPPER U VDE
      400 VAC ±10% 50/60 Hz
      Status indicator
      ECP16 BASE STEPPER U VDE
      Led + Display
      ECP21 BASE STEPPER U VDE
      Led + Display
      Load type
      ECP16 BASE STEPPER U VDE
      Three phase
      ECP21 BASE STEPPER U VDE
      Three phase
      Working temperature
      ECP16 BASE STEPPER U VDE
      -25 ÷ +55°C
      ECP21 BASE STEPPER U VDE
      -25 ÷ +55°C
      Storage temperature
      ECP16 BASE STEPPER U VDE
      -10 ÷ +70°C
      ECP21 BASE STEPPER U VDE
      -10 ÷ +70°C
      Relative ambient humidity
      ECP16 BASE STEPPER U VDE
      < 90% RH without condensate
      ECP21 BASE STEPPER U VDE
      < 90% RH without condensate
      Reading range
      ECP16 BASE STEPPER U VDE
      -45 ÷ +99°C
      ECP21 BASE STEPPER U VDE
      -45 ÷ +99°C
      Room light protection
      ECP16 BASE STEPPER U VDE
      Differential magnetothermic circuit breaker (optional)
      ECP21 BASE STEPPER U VDE
      Differential magnetothermic circuit breaker (optional)
      Main switch / general protection
      ECP16 BASE STEPPER U VDE
      4 poles magnetothermic 32A
      ECP21 BASE STEPPER U VDE
      4 poles magnetothermic 40A
      Control
      ECP16 BASE STEPPER U VDE
      Pego Stepper
      ECP21 BASE STEPPER U VDE
      Pego Stepper
      Alarm signals
      ECP16 BASE STEPPER U VDE
      Led + Buzzer
      ECP21 BASE STEPPER U VDE
      Led + Buzzer
      Insulation transformer
      ECP16 BASE STEPPER U VDE
      Present
      ECP21 BASE STEPPER U VDE
      Present
      Ambient probe
      ECP16 BASE STEPPER U VDE
      NTC 10 kΩ
      ECP21 BASE STEPPER U VDE
      NTC 10 kΩ
      Evaporator probe 1
      ECP16 BASE STEPPER U VDE
      NTC 10 kΩ
      ECP21 BASE STEPPER U VDE
      NTC 10 kΩ
      Suction probe
      ECP16 BASE STEPPER U VDE
      NTC 10 kΩ
      ECP21 BASE STEPPER U VDE
      NTC 10 kΩ
      Evaporation pressure probe
      ECP16 BASE STEPPER U VDE
      4-20 mA (not included)
      ECP21 BASE STEPPER U VDE
      4-20 mA (not included)
      Door switch
      ECP16 BASE STEPPER U VDE
      Present
      ECP21 BASE STEPPER U VDE
      Present
      Man in cold-room alarm
      ECP16 BASE STEPPER U VDE
      Available
      ECP21 BASE STEPPER U VDE
      Available
      Elettronic defrost
      ECP16 BASE STEPPER U VDE
      16500W (3 x 5500) Eq. resistive load
      ECP21 BASE STEPPER U VDE
      21000W (3 x 7000) Eq. resistive load
      Evaporator fans 1
      ECP16 BASE STEPPER U VDE
      2 x 1500W
      ECP21 BASE STEPPER U VDE
      3 x 1500W
      Stepper valve output
      ECP16 BASE STEPPER U VDE
      Bipolar
      ECP21 BASE STEPPER U VDE
      Bipolar
      Enable condensing unit
      ECP16 BASE STEPPER U VDE
      Present
      ECP21 BASE STEPPER U VDE
      Present
      Room light
      ECP16 BASE STEPPER U VDE
      Present
      ECP21 BASE STEPPER U VDE
      Present
      Alarm/AUX relay
      ECP16 BASE STEPPER U VDE
      Present
      ECP21 BASE STEPPER U VDE
      Present
      Supervision
      ECP16 BASE STEPPER U VDE
      TeleNet / Modbus-RTU
      ECP21 BASE STEPPER U VDE
      TeleNet / Modbus-RTU
      Dimension
      ECP16 BASE STEPPER U VDE
      ECP16/21 BASE STEPPER U VDE
      ECP21 BASE STEPPER U VDE
      ECP16/21 BASE STEPPER U VDE
      Connection Scheme
      ECP16 BASE STEPPER U VDE
      ECP16/21 BASE STEPPER U VDE
      ECP21 BASE STEPPER U VDE
      ECP16/21 BASE STEPPER U VDE
      Technical Characteristics
      Inputs
      Outputs
      Dimensions and Diagram
      Available Versions
      ECP16 BASE STEPPER U VDE
      ECP21 BASE STEPPER U VDE
      Product Code
      110016BSUEE0001
      Product Code
      110021BSUEE0001
      Compressor
      Product Code
      110016BSUEE0001
      No
      Evaporator fan
      Product Code
      110016BSUEE0001
      1,5 kW
      Defrosting
      Product Code
      110016BSUEE0001
      16,5 kw
      Electronic expansion valve
      Product Code
      110016BSUEE0001
      Yes
      Man in cold-room alarm
      Product Code
      110016BSUEE0001
      No
      Complete cold room management
      Product Code
      110016BSUEE0001
      No
      Condensing unit management
      Product Code
      110016BSUEE0001
      No
      Temperature/Humidity Management
      Product Code
      110016BSUEE0001
      No
      Evaporating unit management
      Product Code
      110016BSUEE0001
      Yes
      Double system management
      Product Code
      110016BSUEE0001
      No
      Valve management electronic on/off
      Product Code
      110016BSUEE0001
      No
      Valve management Stepper electronics
      Product Code
      110016BSUEE0001
      Yes
      Double evaporator management
      Product Code
      110016BSUEE0001
      No
      Datalogger
      Product Code
      110016BSUEE0001
      No
      Compressor
      Product Code
      110021BSUEE0001
      No
      Evaporator fan
      Product Code
      110021BSUEE0001
      1,5 kW
      Defrosting
      Product Code
      110021BSUEE0001
      21,0 kW
      Electronic expansion valve
      Product Code
      110021BSUEE0001
      Yes
      Man in cold-room alarm
      Product Code
      110021BSUEE0001
      No
      Complete cold room management
      Product Code
      110021BSUEE0001
      No
      Condensing unit management
      Product Code
      110021BSUEE0001
      No
      Temperature/Humidity Management
      Product Code
      110021BSUEE0001
      No
      Evaporating unit management
      Product Code
      110021BSUEE0001
      Yes
      Double system management
      Product Code
      110021BSUEE0001
      No
      Valve management electronic on/off
      Product Code
      110021BSUEE0001
      No
      Valve management Stepper electronics
      Product Code
      110021BSUEE0001
      Yes
      Double evaporator management
      Product Code
      110021BSUEE0001
      No
      Datalogger
      Product Code
      110021BSUEE0001
      No

      Società soggetta all’attività di direzione
      e coordinamento di Castel S.r.l.

      P.I. 01071530297
      Capitale sociale € 100.000,00 i.v.
      Iscrizione Registro Imprese di Rovigo n.01071530297
      REA: 12439

      CONTACT

      Phone: (+39) 0425 762906

      E-Mail: info@pego.it

      Head Office: Via Piacentina, 6/b 45030, Occhiobello (RO)

      Seguici
      sui social

      Copyrights 2024 © Pego | Design and Bulding Teknet.it | Photography ad 3D Models TecnoMedia.biz