PRODUCTS | ELECTRICAL BOARDS
ECP7.5/15/19.5 BASE4 U VDE
POWER AND ELECTRONIC CONTROL PANELS TO MANAGE EVAPORATING UNIT ONLY WITH CIRCUIT BREAKERS PROTECTION
A line of power and electronic control panels to manage the three-phase evaporating unit only where devices are served by a compressor rack. Various power ranges and a wide range of optionals allow you to choose the panel best suited to your system.
Application
-
Control of evaporating unit only with electrical defrost up to 21 kw.
Main characteristic
- Protection of the loads and the auxiliary circuit with circuit breakers.
- Enabling for condensing unit, defrosting elements, evaporator fans, solenoid valve, room light and all standard-compliant electrical safeguards.
- Compact, self-extinguishing ABS housing with IP65 protection rating and circuit breaker on front of panel.
- Control electronics with large backlit LCD and user-friendly keypad.
- LED system status indicators.
- RS485 for connection to TeleNET industrial supervision network or Modbus-RTU standard protocol.
- Free-voltage contact alarm output to activate other warning devices such as sirens or dialers.
Properties
ECP7.5 BASE4 U VDE
ECP15 BASE4 U VDE
ECP19.5 BASE4 U VDE
Dimension
ECP7.5 BASE4 U VDE
290x340x145 mm
ECP15 BASE4 U VDE
350x450x160 mm
ECP19.5 BASE4 U VDE
350x450x160 mm
Weight
ECP7.5 BASE4 U VDE
6kg
ECP15 BASE4 U VDE
6kg
ECP19.5 BASE4 U VDE
7kg
Front protection rating
ECP7.5 BASE4 U VDE
IP 65
ECP15 BASE4 U VDE
IP 65
ECP19.5 BASE4 U VDE
IP 65
Power supply
ECP7.5 BASE4 U VDE
400 VAC ±10% 50/60 Hz
ECP15 BASE4 U VDE
400 VAC ±10% 50/60 Hz
ECP19.5 BASE4 U VDE
400 VAC ±10% 50/60 Hz
Status indicator
ECP7.5 BASE4 U VDE
Led + Display
ECP15 BASE4 U VDE
Led + Display
ECP19.5 BASE4 U VDE
Led + Display
Load type
ECP7.5 BASE4 U VDE
Three phase
ECP15 BASE4 U VDE
Three phase
ECP19.5 BASE4 U VDE
Three phase
Working temperature
ECP7.5 BASE4 U VDE
-5 ÷ +50 °C
ECP15 BASE4 U VDE
-5 ÷ +50 °C
ECP19.5 BASE4 U VDE
-5 ÷ +50 °C
Storage temperature
ECP7.5 BASE4 U VDE
-10 ÷ +70°C
ECP15 BASE4 U VDE
-10 ÷ +70°C
ECP19.5 BASE4 U VDE
-10 ÷ +70°C
Relative ambient humidity
ECP7.5 BASE4 U VDE
< 90% RH without condensate
ECP15 BASE4 U VDE
< 90% RH without condensate
ECP19.5 BASE4 U VDE
< 90% RH without condensate
Reading range
ECP7.5 BASE4 U VDE
-45 ÷ +99°C
ECP15 BASE4 U VDE
-45 ÷ +99°C
ECP19.5 BASE4 U VDE
-45 ÷ +99°C
Door lock main switch
ECP7.5 BASE4 U VDE
16 A
ECP15 BASE4 U VDE
40 A
ECP19.5 BASE4 U VDE
63 A
General protection
ECP7.5 BASE4 U VDE
Magnetothermal switches
ECP15 BASE4 U VDE
Magnetothermal switches
ECP19.5 BASE4 U VDE
Magnetothermal switches
Control
ECP7.5 BASE4 U VDE
Pego
ECP15 BASE4 U VDE
Pego
ECP19.5 BASE4 U VDE
Pego
Alarm signals
ECP7.5 BASE4 U VDE
Led + Buzzer
ECP15 BASE4 U VDE
Led + Buzzer
ECP19.5 BASE4 U VDE
Led + Buzzer
Defrosting
ECP7.5 BASE4 U VDE
Electrical
ECP15 BASE4 U VDE
Electrical
ECP19.5 BASE4 U VDE
Electrical
Insulation transformer
ECP7.5 BASE4 U VDE
Present
ECP15 BASE4 U VDE
Present
ECP19.5 BASE4 U VDE
Present
Ambient probe
ECP7.5 BASE4 U VDE
NTC 10 kΩ
ECP15 BASE4 U VDE
NTC 10 kΩ
ECP19.5 BASE4 U VDE
NTC 10 kΩ
Evaporator probe 1
ECP7.5 BASE4 U VDE
NTC 10 kΩ
ECP15 BASE4 U VDE
NTC 10 kΩ
ECP19.5 BASE4 U VDE
NTC 10 kΩ
Door switch
ECP7.5 BASE4 U VDE
Present
ECP15 BASE4 U VDE
Present
ECP19.5 BASE4 U VDE
Present
Man in cold-room alarm
ECP7.5 BASE4 U VDE
Available
ECP15 BASE4 U VDE
Available
ECP19.5 BASE4 U VDE
Available
Defrosting heaters 1
ECP7.5 BASE4 U VDE
7500W (2500 W x3,AC1)
ECP15 BASE4 U VDE
16500W (5500W x3,AC1)
ECP19.5 BASE4 U VDE
21000W (7000W x3,AC1)
Evaporator fans 1
ECP7.5 BASE4 U VDE
800W (1 PH)
ECP15 BASE4 U VDE
2x2000W (3PH)
ECP19.5 BASE4 U VDE
3x2000W (3 PH)
Solenoid valve 1
ECP7.5 BASE4 U VDE
Present
ECP15 BASE4 U VDE
Present
ECP19.5 BASE4 U VDE
Present
Enable condensing unit
ECP7.5 BASE4 U VDE
Present
ECP15 BASE4 U VDE
Present
ECP19.5 BASE4 U VDE
Present
Room light
ECP7.5 BASE4 U VDE
Present
ECP15 BASE4 U VDE
Present
ECP19.5 BASE4 U VDE
Present
2 Configurable relays
ECP7.5 BASE4 U VDE
Present
ECP15 BASE4 U VDE
Present
ECP19.5 BASE4 U VDE
Present
Supervision
ECP7.5 BASE4 U VDE
TeleNet / Modbus-RTU
ECP15 BASE4 U VDE
TeleNet / Modbus-RTU
ECP19.5 BASE4 U VDE
TeleNet / Modbus-RTU
Technical Characteristics
Inputs
Outputs
Dimensions and Diagram
Available Versions
ECP7.5 BASE4 U VDE
ECP15 BASE4 U VDE
ECP19.5 BASE4 U VDE
Product Code
110BUVDE7.5
Product Code
110BUVDE15
Product Code
110BUVDE19.5
Compressor
Product Code
110BUVDE7.5
110BUVDE7.5
No
Evaporator fan
Product Code
110BUVDE7.5
110BUVDE7.5
0,8 kW
Defrosting
Product Code
110BUVDE7.5
110BUVDE7.5
7,5 kW
Electronic expansion valve
Product Code
110BUVDE7.5
110BUVDE7.5
No
Man in cold-room alarm
Product Code
110BUVDE7.5
110BUVDE7.5
No
Complete cold room management
Product Code
110BUVDE7.5
110BUVDE7.5
No
Condensing unit management
Product Code
110BUVDE7.5
110BUVDE7.5
No
Temperature/Humidity Management
Product Code
110BUVDE7.5
110BUVDE7.5
No
Evaporating unit management
Product Code
110BUVDE7.5
110BUVDE7.5
Yes
Double system management
Product Code
110BUVDE7.5
110BUVDE7.5
No
Valve management electronic on/off
Product Code
110BUVDE7.5
110BUVDE7.5
No
Valve management Stepper electronics
Product Code
110BUVDE7.5
110BUVDE7.5
No
Double evaporator management
Product Code
110BUVDE7.5
110BUVDE7.5
No
Datalogger
Product Code
110BUVDE7.5
110BUVDE7.5
No
Compressor
Product Code
110BUVDE15
110BUVDE15
No
Evaporator fan
Product Code
110BUVDE15
110BUVDE15
2,0 kW
Defrosting
Product Code
110BUVDE15
110BUVDE15
16,5 kw
Electronic expansion valve
Product Code
110BUVDE15
110BUVDE15
No
Man in cold-room alarm
Product Code
110BUVDE15
110BUVDE15
No
Complete cold room management
Product Code
110BUVDE15
110BUVDE15
No
Condensing unit management
Product Code
110BUVDE15
110BUVDE15
No
Temperature/Humidity Management
Product Code
110BUVDE15
110BUVDE15
No
Evaporating unit management
Product Code
110BUVDE15
110BUVDE15
Yes
Double system management
Product Code
110BUVDE15
110BUVDE15
No
Valve management electronic on/off
Product Code
110BUVDE15
110BUVDE15
No
Valve management Stepper electronics
Product Code
110BUVDE15
110BUVDE15
No
Double evaporator management
Product Code
110BUVDE15
110BUVDE15
No
Datalogger
Product Code
110BUVDE15
110BUVDE15
No
Compressor
Product Code
110BUVDE19.5
110BUVDE19.5
No
Evaporator fan
Product Code
110BUVDE19.5
110BUVDE19.5
2,0 kW
Defrosting
Product Code
110BUVDE19.5
110BUVDE19.5
21,0 kW
Electronic expansion valve
Product Code
110BUVDE19.5
110BUVDE19.5
No
Man in cold-room alarm
Product Code
110BUVDE19.5
110BUVDE19.5
No
Complete cold room management
Product Code
110BUVDE19.5
110BUVDE19.5
No
Condensing unit management
Product Code
110BUVDE19.5
110BUVDE19.5
No
Temperature/Humidity Management
Product Code
110BUVDE19.5
110BUVDE19.5
No
Evaporating unit management
Product Code
110BUVDE19.5
110BUVDE19.5
Yes
Double system management
Product Code
110BUVDE19.5
110BUVDE19.5
No
Valve management electronic on/off
Product Code
110BUVDE19.5
110BUVDE19.5
No
Valve management Stepper electronics
Product Code
110BUVDE19.5
110BUVDE19.5
No
Double evaporator management
Product Code
110BUVDE19.5
110BUVDE19.5
No
Datalogger
Product Code
110BUVDE19.5
110BUVDE19.5
No