Skip to main content
PRODUCTS | ELECTRICAL BOARDS
ECP 30

A SIMPLE, COMPACT SOLUTION FOR CONTROL OF THREE-PHASE CONDENSING UNITS

A SIMPLE, COMPACT SOLUTION FOR CONTROL OF THREE-PHASE CONDENSING UNITS
A SIMPLE, COMPACT SOLUTION FOR CONTROL OF THREE-PHASE CONDENSING UNITS

    A simple, compact solution for control of three-phase condensing units up to 30 HP.
    The call can be generated by pressure switch (compressor shutdown in pump-down mode), thermostat or clean contact.

    Available version with PWS compressor.

    A SIMPLE, COMPACT SOLUTION FOR CONTROL OF THREE-PHASE CONDENSING UNITS
    A SIMPLE, COMPACT SOLUTION FOR CONTROL OF THREE-PHASE CONDENSING UNITS
      Applications
      • Control of condensing unit with three-phase compressor up to 30 HP.

      Main characteristics
      • Direct control of compressor, condenser fans and all standard-compliant electrical safeguards.
      • Compressor call by pressure switch, thermostat or clean contact.
      • Compact unit with self-extinguishing ABS panel and IP65 protection rating plus circuit breaker on front of panel.
      • System status indicated by LED icon.
      Properties
       
      ECP 30
      ECP 30 PWS
      Dimension
      ECP 30
      470x650x210 mm
      ECP 30 PWS
      470x650x210 mm
      Weight
      ECP 30
      10kg
      ECP 30 PWS
      10kg
      Front protection rating
      ECP 30
      IP 65
      ECP 30 PWS
      IP 65
      Power supply
      ECP 30
      400 VAC ±10% 50/60 Hz
      ECP 30 PWS
      400 VAC ±10% 50/60 Hz
      Status indicator
      ECP 30
      Led
      ECP 30 PWS
      Led
      Load type
      ECP 30
      Three phase
      ECP 30 PWS
      Three phase
      Working temperature
      ECP 30
      -5 ÷ +50 °C
      ECP 30 PWS
      -5 ÷ +50 °C
      Storage temperature
      ECP 30
      -10 ÷ +70°C
      ECP 30 PWS
      -10 ÷ +70°C
      Relative ambient humidity
      ECP 30
      30% - 90% RH without condensate
      ECP 30 PWS
      30% - 90% RH without condensate
      Door lock main switch
      ECP 30
      125 A
      ECP 30 PWS
      125 A
      Compressor protection
      ECP 30
      Motor circuit breaker
      ECP 30 PWS
      Motor circuit breaker
      General protection
      ECP 30
      Magnetothermal switches
      ECP 30 PWS
      Magnetothermal switches
      Control
      ECP 30
      External pressure switch
      ECP 30 PWS
      External pressure switch
      Insulation transformer
      ECP 30
      Present
      ECP 30 PWS
      Present
      Pump-down stop
      ECP 30
      Present
      ECP 30 PWS
      Present
      Oil pressure switch
      ECP 30
      Present
      ECP 30 PWS
      Present
      Condenser fans regulator press. switch (r.p.s.)
      ECP 30
      Present
      ECP 30 PWS
      Present
      Thermostat or pressure switch
      ECP 30
      Present
      ECP 30 PWS
      Present
      Kriwan® connection
      ECP 30
      Present
      ECP 30 PWS
      Present
      Compressor
      ECP 30
      15000÷22400W (20÷30 HP)
      ECP 30 PWS
      PWS 15000÷22400W (20÷30 HP)
      Condenser fans output 1
      ECP 30
      2000W(3PH) or 1500W (1PH)
      ECP 30 PWS
      Separated 2000W(3PH) or 1500W (1PH)
      Condenser fans output 3
      ECP 30
      Separated 2000W(3PH) or 1500W (1PH)
      ECP 30 PWS
      Separated 2000W(3PH) or 1500W (1PH)
      Condenser fans output 4
      ECP 30
      Separated 2000W(3PH) or 1500W (1PH)
      ECP 30 PWS
      Separated 2000W(3PH) or 1500W (1PH)
      Condenser fans output 2 (separated)
      ECP 30
      Separated 2000W(3PH) or 1500W (1PH)
      ECP 30 PWS
      Separated 2000W(3PH) or 1500W (1PH)
      Compressor oil heater
      ECP 30
      Present
      ECP 30 PWS
      Present
      Dimension
      ECP 30
      ECP 30
      ECP 30 PWS
      ECP 30
      Connection Scheme
      ECP 30
      ECP 30
      ECP 30 PWS
      ECP 30
      Technical Characteristics
      Inputs
      Outputs
      Dimensions and Diagram
      Available Versions
      ECP 30
      ECP 30 PWS
      Product Code
      10030B01
      10030B02
      10030B03
      10030B04
      Product Code
      10030BE01
      10030BE02
      10030BE03
      Compressor
      Product Code
      10030B01
      42.0 - 52.0 A
      Product Code
      10030B02
      49.0 - 59.0 A
      Product Code
      10030B03
      54.0 - 65.0 A
      Product Code
      10030B04
      32.0 - 40.0 A
      Evaporator fan
      Product Code
      10030B01
      2,0 kW
      Product Code
      10030B02
      2,0 kW
      Product Code
      10030B03
      2,0 kW
      Product Code
      10030B04
      2,0 kW
      Defrosting
      Product Code
      10030B01
      No
      Product Code
      10030B02
      No
      Product Code
      10030B03
      No
      Product Code
      10030B04
      No
      Electronic expansion valve
      Product Code
      10030B01
      No
      Product Code
      10030B02
      No
      Product Code
      10030B03
      No
      Product Code
      10030B04
      No
      Man in cold-room alarm
      Product Code
      10030B01
      No
      Product Code
      10030B02
      No
      Product Code
      10030B03
      No
      Product Code
      10030B04
      No
      Complete cold room management
      Product Code
      10030B01
      No
      Product Code
      10030B02
      No
      Product Code
      10030B03
      No
      Product Code
      10030B04
      No
      Condensing unit management
      Product Code
      10030B01
      Yes
      Product Code
      10030B02
      Yes
      Product Code
      10030B03
      Yes
      Product Code
      10030B04
      Yes
      Temperature/Humidity Management
      Product Code
      10030B01
      No
      Product Code
      10030B02
      No
      Product Code
      10030B03
      No
      Product Code
      10030B04
      No
      Evaporating unit management
      Product Code
      10030B01
      No
      Product Code
      10030B02
      No
      Product Code
      10030B03
      No
      Product Code
      10030B04
      No
      Double system management
      Product Code
      10030B01
      No
      Product Code
      10030B02
      No
      Product Code
      10030B03
      No
      Product Code
      10030B04
      No
      Valve management electronic on/off
      Product Code
      10030B01
      No
      Product Code
      10030B02
      No
      Product Code
      10030B03
      No
      Product Code
      10030B04
      No
      Valve management Stepper electronics
      Product Code
      10030B01
      No
      Product Code
      10030B02
      No
      Product Code
      10030B03
      No
      Product Code
      10030B04
      No
      Double evaporator management
      Product Code
      10030B01
      No
      Product Code
      10030B02
      No
      Product Code
      10030B03
      No
      Product Code
      10030B04
      No
      Datalogger
      Product Code
      10030B01
      No
      Product Code
      10030B02
      No
      Product Code
      10030B03
      No
      Product Code
      10030B04
      No
      Compressor
      Product Code
      10030BE01
      23.0 - 28.0 A
      Product Code
      10030BE02
      27.0 - 32.0 A
      Product Code
      10030BE03
      30.0 - 36.0 A
      Evaporator fan
      Product Code
      10030BE01
      2,0 kW
      Product Code
      10030BE02
      2,0 kW
      Product Code
      10030BE03
      2,0 kW
      Defrosting
      Product Code
      10030BE01
      No
      Product Code
      10030BE02
      No
      Product Code
      10030BE03
      No
      Electronic expansion valve
      Product Code
      10030BE01
      No
      Product Code
      10030BE02
      No
      Product Code
      10030BE03
      No
      Man in cold-room alarm
      Product Code
      10030BE01
      No
      Product Code
      10030BE02
      No
      Product Code
      10030BE03
      No
      Complete cold room management
      Product Code
      10030BE01
      No
      Product Code
      10030BE02
      No
      Product Code
      10030BE03
      No
      Condensing unit management
      Product Code
      10030BE01
      Yes
      Product Code
      10030BE02
      Yes
      Product Code
      10030BE03
      Yes
      Temperature/Humidity Management
      Product Code
      10030BE01
      No
      Product Code
      10030BE02
      No
      Product Code
      10030BE03
      No
      Evaporating unit management
      Product Code
      10030BE01
      No
      Product Code
      10030BE02
      No
      Product Code
      10030BE03
      No
      Double system management
      Product Code
      10030BE01
      No
      Product Code
      10030BE02
      No
      Product Code
      10030BE03
      No
      Valve management electronic on/off
      Product Code
      10030BE01
      No
      Product Code
      10030BE02
      No
      Product Code
      10030BE03
      No
      Valve management Stepper electronics
      Product Code
      10030BE01
      No
      Product Code
      10030BE02
      No
      Product Code
      10030BE03
      No
      Double evaporator management
      Product Code
      10030BE01
      No
      Product Code
      10030BE02
      No
      Product Code
      10030BE03
      No
      Datalogger
      Product Code
      10030BE01
      No
      Product Code
      10030BE02
      No
      Product Code
      10030BE03
      No

      Società soggetta all’attività di direzione
      e coordinamento di Castel S.r.l.

      P.I. 01071530297
      Capitale sociale € 100.000,00 i.v.
      Iscrizione Registro Imprese di Rovigo n.01071530297
      REA: 12439

      CONTACT

      Phone: (+39) 0425 762906

      E-Mail: info@pego.it

      Head Office: Via Piacentina, 6/b 45030, Occhiobello (RO)

      Seguici
      sui social

      Copyrights 2024 © Pego | Design and Bulding Teknet.it | Photography ad 3D Models TecnoMedia.biz