A LINE OF POWER BOARDS FOR REFRIGERATION SYSTEMS

A LINE OF POWER BOARDS FOR REFRIGERATION SYSTEMS
A LINE OF POWER BOARDS FOR REFRIGERATION SYSTEMS

    A line of power boards for refrigeration systems with three-phase compressors up to 3 HP to be linked to a thermostat, thermo-regulator or out-of-room control unit. An electromechanical timer is incorporated for timed defrosts.

    A LINE OF POWER BOARDS FOR REFRIGERATION SYSTEMS
    A LINE OF POWER BOARDS FOR REFRIGERATION SYSTEMS
      Applications
      • Control of three-phase static or ventilated refrigeration units up to 3 HP, with electric or off-cycle defrost linked to a thermostat, thermo-regulator or out-of-room control unit that issues a cold request.

      Main characteristics
      • Direct control of compressor, condenser fans, compressor oil element, defrost elements, evaporator fans, solenoid valve and all standard-compliant electrical safeguards.
      • Compact unit with self-extinguishing ABS housing panel and IP65 protection rating plus circuit breaker on front of panel.
      • Electromechanical timer for timed defrosts.
      • System status indicated by LED icon.
      • Can be controlled by thermostat, thermo-regulator or out-of-room control unit.
      • Can house thermo-regulator on front of panel.
      Options
      • Installation of magnetothermic circuit breakers instead of fuses.
      • Compressor shutdown in pump-down mode.
      Properties
      Dimension
      ECP 300 VD
      290x340x145 mm
      Weight
      ECP 300 VD
      5kg
      Front protection rating
      ECP 300 VD
      IP 65
      Power supply
      ECP 300 VD
      400 VAC ±10% 50/60 Hz
      Status indicator
      ECP 300 VD
      Led
      Load type
      ECP 300 VD
      Three phase
      Working temperature
      ECP 300 VD
      -5 ÷ +50 °C
      Storage temperature
      ECP 300 VD
      -10 ÷ +70°C
      Relative ambient humidity
      ECP 300 VD
      30% - 90% RH without condensate
      Door lock main switch
      ECP 300 VD
      16 A
      Compressor protection
      ECP 300 VD
      Thermal relay
      General protection
      ECP 300 VD
      Fuses
      Control
      ECP 300 VD
      External ON/OFF external thermoregulator - remote control panel
      Alarm signals
      ECP 300 VD
      Led
      Defrosting
      ECP 300 VD
      Electrical
      High/low pressure switch
      ECP 300 VD
      Present
      Thermostat or pressure switch
      ECP 300 VD
      Present
      Thermostat or pressure switch
      ECP 300 VD
      Present
      Kriwan® connection
      ECP 300 VD
      Present
      Compressor
      ECP 300 VD
      2200W (0,5÷3 HP)
      Defrosting heaters 1
      ECP 300 VD
      4000W (AC1)
      Evaporator fans 1
      ECP 300 VD
      800W (1PH)
      Condenser fans output 1
      ECP 300 VD
      800W (1PH)
      Solenoid valve 1
      ECP 300 VD
      Present
      Dimension
      ECP 300 VD
      ECP 300 VD
      Connection Scheme
      ECP 300 VD
      ECP 300 VD
      Technical Characteristics
      Inputs
      Outputs
      Dimensions and Diagram
      Available Versions
      ECP 300 VD
      Product Code
      100300VD021
      100300VD022
      100300VD023
      100300VD025
      100300VD026
      100300VD027
      100300VD028
      100300VD029
      Compressor
      Product Code
      100300VD021
      1.1 - 1.6 A
      Product Code
      100300VD022
      1.8 - 2.5 A
      Product Code
      100300VD023
      2.8 - 4.0 A
      -
      Product Code
      100300VD025
      5.5 - 8.0 A
      Product Code
      100300VD026
      7.0 - 10.0 A
      Product Code
      100300VD027
      1.4 - 2.0 A
      Product Code
      100300VD028
      3.5 - 5.0 A
      Product Code
      100300VD029
      2.2 - 3.2 A
      Evaporator fan
      Product Code
      100300VD021
      0,8 kW
      Product Code
      100300VD022
      0,8 kW
      Product Code
      100300VD023
      0,8 kW
      -
      Product Code
      100300VD025
      0,8 kW
      Product Code
      100300VD026
      0,8 kW
      Product Code
      100300VD027
      0,8 kW
      Product Code
      100300VD028
      0,8 kW
      Product Code
      100300VD029
      0,8 kW
      Defrosting
      Product Code
      100300VD021
      4,0 kW
      Product Code
      100300VD022
      4,0 kW
      Product Code
      100300VD023
      4,0 kW
      -
      Product Code
      100300VD025
      4,0 kW
      Product Code
      100300VD026
      4,0 kW
      Product Code
      100300VD027
      4,0 kW
      Product Code
      100300VD028
      4,0 kW
      Product Code
      100300VD029
      4,0 kW
      Electronic expansion valve
      Product Code
      100300VD021
      No
      Product Code
      100300VD022
      No
      Product Code
      100300VD023
      No
      Product Code
      No
      Product Code
      100300VD025
      No
      Product Code
      100300VD026
      No
      Product Code
      100300VD027
      No
      Product Code
      100300VD028
      No
      Product Code
      100300VD029
      No
      Man in cold-room alarm
      Product Code
      100300VD021
      No
      Product Code
      100300VD022
      No
      Product Code
      100300VD023
      No
      Product Code
      No
      Product Code
      100300VD025
      No
      Product Code
      100300VD026
      No
      Product Code
      100300VD027
      No
      Product Code
      100300VD028
      No
      Product Code
      100300VD029
      No
      Complete cold room management
      Product Code
      100300VD021
      Yes
      Product Code
      100300VD022
      Yes
      Product Code
      100300VD023
      Yes
      Product Code
      No
      Product Code
      100300VD025
      Yes
      Product Code
      100300VD026
      Yes
      Product Code
      100300VD027
      Yes
      Product Code
      100300VD028
      Yes
      Product Code
      100300VD029
      Yes
      Condensing unit management
      Product Code
      100300VD021
      No
      Product Code
      100300VD022
      No
      Product Code
      100300VD023
      No
      Product Code
      No
      Product Code
      100300VD025
      No
      Product Code
      100300VD026
      No
      Product Code
      100300VD027
      No
      Product Code
      100300VD028
      No
      Product Code
      100300VD029
      No
      Temperature/Humidity Management
      Product Code
      100300VD021
      No
      Product Code
      100300VD022
      No
      Product Code
      100300VD023
      No
      Product Code
      No
      Product Code
      100300VD025
      No
      Product Code
      100300VD026
      No
      Product Code
      100300VD027
      No
      Product Code
      100300VD028
      No
      Product Code
      100300VD029
      No
      Evaporating unit management
      Product Code
      100300VD021
      No
      Product Code
      100300VD022
      No
      Product Code
      100300VD023
      No
      Product Code
      No
      Product Code
      100300VD025
      No
      Product Code
      100300VD026
      No
      Product Code
      100300VD027
      No
      Product Code
      100300VD028
      No
      Product Code
      100300VD029
      No
      Double system management
      Product Code
      100300VD021
      No
      Product Code
      100300VD022
      No
      Product Code
      100300VD023
      No
      Product Code
      No
      Product Code
      100300VD025
      No
      Product Code
      100300VD026
      No
      Product Code
      100300VD027
      No
      Product Code
      100300VD028
      No
      Product Code
      100300VD029
      No
      Valve management electronic on/off
      Product Code
      100300VD021
      No
      Product Code
      100300VD022
      No
      Product Code
      100300VD023
      No
      Product Code
      No
      Product Code
      100300VD025
      No
      Product Code
      100300VD026
      No
      Product Code
      100300VD027
      No
      Product Code
      100300VD028
      No
      Product Code
      100300VD029
      No
      Valve management Stepper electronics
      Product Code
      100300VD021
      No
      Product Code
      100300VD022
      No
      Product Code
      100300VD023
      No
      Product Code
      No
      Product Code
      100300VD025
      No
      Product Code
      100300VD026
      No
      Product Code
      100300VD027
      No
      Product Code
      100300VD028
      No
      Product Code
      100300VD029
      No
      Double evaporator management
      Product Code
      100300VD021
      No
      Product Code
      100300VD022
      No
      Product Code
      100300VD023
      No
      Product Code
      No
      Product Code
      100300VD025
      No
      Product Code
      100300VD026
      No
      Product Code
      100300VD027
      No
      Product Code
      100300VD028
      No
      Product Code
      100300VD029
      No
      Datalogger
      Product Code
      100300VD021
      No
      Product Code
      100300VD022
      No
      Product Code
      100300VD023
      No
      Product Code
      No
      Product Code
      100300VD025
      No
      Product Code
      100300VD026
      No
      Product Code
      100300VD027
      No
      Product Code
      100300VD028
      No
      Product Code
      100300VD029
      No

      Società soggetta all’attività di direzione
      e coordinamento di Castel S.r.l.

      P.I. 01071530297
      Capitale sociale € 100.000,00 i.v.
      Iscrizione Registro Imprese di Rovigo n.01071530297
      REA: 12439

      CONTACT

      Phone: (+39) 0425 762906

      E-Mail: info@pego.it

      Head Office: Via Piacentina, 6/b 45030, Occhiobello (RO)

      Seguici
      sui social

      Copyrights 2024 © Pego | Design and Bulding Teknet.it | Photography ad 3D Models TecnoMedia.biz