CONTROL PANEL FOR PULSE ELECTRONIC EXPANSION VALVE
Electrical panel for cold room control with differential magnetothermic circuit breaker and with integrated command of pulse electronic expansion valve 230Vac On/Off and single-phase compressor up to 2HP. This panel can be used also only for the control of the evaporating unit.
Applications
-
Complete control of single-phase static or ventilated refrigeration systems up to 2 HP, with off-cycle or electrical defrosting and direct or pump-down compressor stop.
-
Thought for systems with evaporator managed by ON/OFF electronic expansion valve at 230 Vac.
-
Utility for managing the single-phase evaporating unit with electronic expansion valve only ON/OFF at 230 Vac.
Main characteristics
- Compatible with 22 gases: R404, R134, R22, R407A, R407F, R407H, R410A, R450A, R507, R513A, R744(CO2), R449A, R290, R32, R448A, R452A, R600, R600A, R1270, R1234ze, R23, R717(NH3).
- Defrost with real time clock.
- Indipendent and separated functions for alarm relay and TeleNET or Modbus-RTU standard protocol.
- Control of electronic expansion valve ON/OFF with 230 VAC coil.
- The integration of the valve control permits its programming and a simplified management with the same display, enabling an immediate start-up of the system.
- Direct control of compressor, defrosting heaters, evaporator fans and room light with free-voltage outputs.
- Built-in differential magnetothermic breaker for protection and cut-off of refrigeration unit.
- Innovative, stylish design. Transparent cover for access to magnetothermic breaker, all with IP 65 protection rating.
- Auxiliary relay with parameter-configured activation (alarm, temperature set-point, direct control via frontal pushbutton, thermostat-holder demisting element).
- RS485 for connection to TeleNET industrial supervision network or Modbus-RTU standard protocol.
- Easy installation and opening thanks to new hinged cover.
- Simple, flexible programming gives extreme versatility of use.
- Compressor can be run in pump-down stop mode.
- Installation times and costs reduced thanks to incorporation of control and protection in a single room-dedicated unit.
Properties
Dimension
ECP 200 EXPERT PULSE
263 x 180 x 96 mm
Weight
ECP 200 EXPERT PULSE
1,3kg
Front protection rating
ECP 200 EXPERT PULSE
IP 65
Power supply
ECP 200 EXPERT PULSE
230 VAC ±10% 50/60 Hz
Status indicator
ECP 200 EXPERT PULSE
Led + Display
Load type
ECP 200 EXPERT PULSE
Single phase
Working temperature
ECP 200 EXPERT PULSE
-5 ÷ +50 °C
Storage temperature
ECP 200 EXPERT PULSE
-10 ÷ +70°C
Relative ambient humidity
ECP 200 EXPERT PULSE
30% - 90% RH without condensate
Reading range
ECP 200 EXPERT PULSE
-45 ÷ +99°C
Control
ECP 200 EXPERT PULSE
Pego
Alarm signals
ECP 200 EXPERT PULSE
Led + Buzzer
Defrosting
ECP 200 EXPERT PULSE
Electrical (RTC)
Resolution
ECP 200 EXPERT PULSE
0,1 °C
Compressor functioning mode selection
ECP 200 EXPERT PULSE
Pump Down - Thermostat
Ambient probe
ECP 200 EXPERT PULSE
NTC 10 kΩ
Evaporator probe 1
ECP 200 EXPERT PULSE
NTC 10 kΩ
Suction probe
ECP 200 EXPERT PULSE
NTC 10 kΩ
Evaporation pressure probe
ECP 200 EXPERT PULSE
4-20mA / 0-5V RATIO
Door switch
ECP 200 EXPERT PULSE
Present
High/low pressure switch
ECP 200 EXPERT PULSE
Present
Man in cold-room alarm
ECP 200 EXPERT PULSE
Present
Compressor
ECP 200 EXPERT PULSE
1500W (AC3)
Defrosting heaters 1
ECP 200 EXPERT PULSE
3000W (AC1) free voltage contact
Evaporator fans
ECP 200 EXPERT PULSE
500W (AC3) free voultage contact
Electronic expansion valve
ECP 200 EXPERT PULSE
Pulse 230 VAC
Room light
ECP 200 EXPERT PULSE
800W (AC1) free voltage contact
Alarm/AUX relay
ECP 200 EXPERT PULSE
100W free voltage contact
Supervision
ECP 200 EXPERT PULSE
TeleNet / Modbus-RTU
Technical Characteristics
Inputs