PRODUCTS | ELECTRICAL BOARDS
ECP 202 EXPERT
CONTROL PANEL FOR COLD ROOMS
Control panel for cold rooms with single-phase compressor up to 2 HP, specially designed to provide safety, protection, control and easy-installation – all in one unit. It allows a complete control of all the components on a refrigeration system.
Applications
-
Complete control of single-phase static or ventilated refrigeration systems up to 2 HP, with off-cycle or electrical defrosting and direct or pump-down compressor stop.
-
Control of single-phase evaporating unit with solenoid valve and remote motor condenser enabling.
Main characteristics
- Direct control of compressor, defrosting heaters, evaporator fans and room light with live outputs directly connectable to the various devices or free voltage contacts for control of condensing unit with its own electrical panel.
- Built-in differential magnetothermic breaker for protection and cut-off of refrigeration unit.
- Innovative, stylish design. Lockable transparent cover for access to magnetothermic breaker, all with IP65 protection rating.
- 2 auxiliary relays with parameter-configured activation (alarm, temperature set-point, direct control via frontal pushbutton, door heater elements, remote motor condenser unit enabling, solenoid valve control enabling where compressor pump-down operation is applied, stand-by).
- RS485 for connection to TeleNET industrial supervision network or Modbus-RTU standard protocol.
- Easy installation and opening thanks to new hinged cover.
- Can be configured for hot applications or cold applications.
- Functions for energy saving.
Properties
ECP 202 EXPERT
ECP 202 EXPERT CR
Dimension
ECP 202 EXPERT
263 x 180 x 96 mm
ECP 202 EXPERT CR
263 x 180 x 96 mm
Weight
ECP 202 EXPERT
1,3kg
ECP 202 EXPERT CR
1,3kg
Front protection rating
ECP 202 EXPERT
IP 65
ECP 202 EXPERT CR
IP 65
Power supply
ECP 202 EXPERT
230 VAC ±10% 50/60Hz
ECP 202 EXPERT CR
230 VAC ±10% 50/60 Hz
Status indicator
ECP 202 EXPERT
Led + Display
ECP 202 EXPERT CR
Led + Display
Max absorbed power
ECP 202 EXPERT
7 VA
ECP 202 EXPERT CR
-
Working temperature
ECP 202 EXPERT
-5 ÷ +40°C
ECP 202 EXPERT CR
-5 ÷ +40°C
Storage temperature
ECP 202 EXPERT
-10 ÷ +70°C
ECP 202 EXPERT CR
-10 ÷ +70 °C
Relative ambient humidity
ECP 202 EXPERT
30% - 90% RH without condensate
ECP 202 EXPERT CR
30% - 90% RH without condensate
Reading range
ECP 202 EXPERT
-45 ÷ +99°C
ECP 202 EXPERT CR
-45 ÷ +99°C
Main switch / general protection
ECP 202 EXPERT
16A ID= 300 mA Potere d'interruzione 4,5 kA ID=30 mA (su richiesta)
ECP 202 EXPERT CR
16A ID= 300 mA Potere d'interruzione 4,5 kA ID=30 mA (su richiesta)
Control
ECP 202 EXPERT
Pego
ECP 202 EXPERT CR
Pego
Alarm signals
ECP 202 EXPERT
Led + Buzzer
ECP 202 EXPERT CR
Led + Buzzer
Probe read precision
ECP 202 EXPERT
±0,5 °C
ECP 202 EXPERT CR
±0,5 °C
Defrosting
ECP 202 EXPERT
Electrical
ECP 202 EXPERT CR
Electrical
Resolution
ECP 202 EXPERT
0,1 °C
ECP 202 EXPERT CR
0,1 °C
Ambient probe
ECP 202 EXPERT
NTC 10 kΩ
ECP 202 EXPERT CR
NTC 10 kΩ
Evaporator probe 1
ECP 202 EXPERT
NTC 10 kΩ
ECP 202 EXPERT CR
NTC 10 kΩ
Door switch
ECP 202 EXPERT
Present
ECP 202 EXPERT CR
Present
High/low pressure switch
ECP 202 EXPERT
Present
ECP 202 EXPERT CR
Present
Man in cold-room alarm
ECP 202 EXPERT
Present
ECP 202 EXPERT CR
Present
Compressor
ECP 202 EXPERT
1500W (2 HP)
ECP 202 EXPERT CR
1500W (2HP) free voltage contact
Defrosting
ECP 202 EXPERT
3000W (AC1)
ECP 202 EXPERT CR
3000W (AC1)
Defrosting heaters 1
ECP 202 EXPERT
-
ECP 202 EXPERT CR
3000W (AC1) free voltage contact
Evaporator fans
ECP 202 EXPERT
500W (AC3)
ECP 202 EXPERT CR
500W (AC3) free voultage contact
Room light
ECP 202 EXPERT
800W (AC1)
ECP 202 EXPERT CR
800W (AC1) free voltage contact
Supervision
ECP 202 EXPERT
TeleNet / Modbus-RTU
ECP 202 EXPERT CR
TeleNet / Modbus-RTU
Technical Characteristics
Inputs
Outputs
Dimensions and Diagram
Available Versions
ECP 202 EXPERT
Product Code
200202EXPBCS
200202EXPCS
Compressor
Product Code
200202EXPBCS
200202EXPBCS
Monofase
Product Code
200202EXPCS
200202EXPCS
Monofase
Evaporator fan
Product Code
200202EXPBCS
200202EXPBCS
0,5 kW
Product Code
200202EXPCS
200202EXPCS
0,5 kW
Defrosting
Product Code
200202EXPBCS
200202EXPBCS
3,0 kW
Product Code
200202EXPCS
200202EXPCS
3,0 kW
Electronic expansion valve
Product Code
200202EXPBCS
200202EXPBCS
No
Product Code
200202EXPCS
200202EXPCS
No
Man in cold-room alarm
Product Code
200202EXPBCS
200202EXPBCS
No
Product Code
200202EXPCS
200202EXPCS
No
Complete cold room management
Product Code
200202EXPBCS
200202EXPBCS
Yes
Product Code
200202EXPCS
200202EXPCS
Yes
Condensing unit management
Product Code
200202EXPBCS
200202EXPBCS
No
Product Code
200202EXPCS
200202EXPCS
No
Temperature/Humidity Management
Product Code
200202EXPBCS
200202EXPBCS
No
Product Code
200202EXPCS
200202EXPCS
No
Evaporating unit management
Product Code
200202EXPBCS
200202EXPBCS
No
Product Code
200202EXPCS
200202EXPCS
No
Double system management
Product Code
200202EXPBCS
200202EXPBCS
No
Product Code
200202EXPCS
200202EXPCS
No
Valve management electronic on/off
Product Code
200202EXPBCS
200202EXPBCS
No
Product Code
200202EXPCS
200202EXPCS
No
Valve management Stepper electronics
Product Code
200202EXPBCS
200202EXPBCS
No
Product Code
200202EXPCS
200202EXPCS
No
Double evaporator management
Product Code
200202EXPBCS
200202EXPBCS
No
Product Code
200202EXPCS
200202EXPCS
No
Datalogger
Product Code
200202EXPBCS
200202EXPBCS
No
Product Code
200202EXPCS
200202EXPCS
No
Compressor
Evaporator fan
Defrosting
Electronic expansion valve
Man in cold-room alarm
Complete cold room management
Condensing unit management
Temperature/Humidity Management
Evaporating unit management
Double system management
Valve management electronic on/off
Valve management Stepper electronics
Double evaporator management
Datalogger