Skip to main content
PRODUCTS | ELECTRICAL BOARDS
ECP300 EXPERT STEPPER U VD

LINE OF ELECTRICAL PANELS, WITH POWER AND CONTROL OF THE STEPPER ELECTRONIC EXPANSION VALVE (STEPPER MOTOR), DEDICATED TO THE MANAGEMENT OF THE THREE-PHASE EVAPORATING UNIT.

LINE OF ELECTRICAL PANELS, WITH POWER AND CONTROL OF THE STEPPER ELECTRONIC EXPANSION VALVE (STEPPER MOTOR), DEDICATED TO THE MANAGEMENT OF THE THREE-PHASE EVAPORATING UNIT.
LINE OF ELECTRICAL PANELS, WITH POWER AND CONTROL OF THE STEPPER ELECTRONIC EXPANSION VALVE (STEPPER MOTOR), DEDICATED TO THE MANAGEMENT OF THE THREE-PHASE EVAPORATING UNIT.

    ELECTRICAL BOARDSLine of electrical panels, with power and control of the stepper electronic expansion valve (stepper motor), dedicated to control only the three-phase evaporating unit where units are served by a central refrigerator or remote condenser unit. Magnetothermic and differential protection for room light accessible from the front panel linked to an innovative form makes it a perfect and functional choice.

    LINE OF ELECTRICAL PANELS, WITH POWER AND CONTROL OF THE STEPPER ELECTRONIC EXPANSION VALVE (STEPPER MOTOR), DEDICATED TO THE MANAGEMENT OF THE THREE-PHASE EVAPORATING UNIT.
    LINE OF ELECTRICAL PANELS, WITH POWER AND CONTROL OF THE STEPPER ELECTRONIC EXPANSION VALVE (STEPPER MOTOR), DEDICATED TO THE MANAGEMENT OF THE THREE-PHASE EVAPORATING UNIT.
      Applications
      • Control of the evaporating unit, with electrical defrostup to 12 kW.

      • Management of the motorized bipolar expansion valve.

      Main characteristics
      • Driver for the motorized electronic valve integrated in the cold room control.
      • Single display for complete cold room management.
      • Connectable to any type of stepper valve on the market.
      • Including parameters self-configuration table based on the brand and model of the valve.
      • Internal USB port for updates with new refrigerant gases.
      • Enabling for condensing unit, defrost heaters, evaporator fans, solenoid valve, cold room light and presence of all the electrical protections required by regulations.
      • Protection of the loads and of the auxiliary circuit with circuit breakers.
      • Differential magnetothermic dedicated to room light accessible from the front panel (see the table).
      • Easy wiring on the internal terminal block.
      • Compact, self-extinguishing abs housing with IP65 protection rating and circuit breaker on the front of the panel.
        •Electronic control with large LED display and easy-to-use keyboard.
      • LED system status indicators.
      • RS485 serial port for connection to the TeleNET industrial supervision network or standard Modbus-RTU protocol.
      • Alarm output with voltage-free contact to activate other warning devices such as sirens or telephone dialer.
      Properties
       
      ECP300 EXPERT STEPPER U VD 01
      ECP300 EXPERT STEPPER U VD 02
      Dimension
      ECP300 EXPERT STEPPER U VD 01
      400 x 300 x 135 mm
      ECP300 EXPERT STEPPER U VD 02
      400 x 300 x 135 mm
      Weight
      ECP300 EXPERT STEPPER U VD 01
      7kg
      ECP300 EXPERT STEPPER U VD 02
      9kg
      Front protection rating
      ECP300 EXPERT STEPPER U VD 01
      IP 65
      ECP300 EXPERT STEPPER U VD 02
      IP 65
      Power supply
      ECP300 EXPERT STEPPER U VD 01
      400 VAC ±10% 50/60 Hz
      ECP300 EXPERT STEPPER U VD 02
      400 VAC ±10% 50/60 Hz
      Status indicator
      ECP300 EXPERT STEPPER U VD 01
      Led + Display
      ECP300 EXPERT STEPPER U VD 02
      Led + Display
      Load type
      ECP300 EXPERT STEPPER U VD 01
      Three phase
      ECP300 EXPERT STEPPER U VD 02
      Three phase
      Working temperature
      ECP300 EXPERT STEPPER U VD 01
      -5 ÷ +40°C
      ECP300 EXPERT STEPPER U VD 02
      -5 ÷ +40°C
      Storage temperature
      ECP300 EXPERT STEPPER U VD 01
      -25 ÷ +55°C
      ECP300 EXPERT STEPPER U VD 02
      -10 ÷ +70°C
      Relative ambient humidity
      ECP300 EXPERT STEPPER U VD 01
      < 90% RH without condensate
      ECP300 EXPERT STEPPER U VD 02
      30% - 90% RH without condensate
      Reading range
      ECP300 EXPERT STEPPER U VD 01
      -45 ÷ +99°C
      ECP300 EXPERT STEPPER U VD 02
      -45 ÷ +99°C
      Room light protection
      ECP300 EXPERT STEPPER U VD 01
      Differential magnetothermic circuit breaker (optional)
      ECP300 EXPERT STEPPER U VD 02
      Differential magnetothermic circuit breaker (optional)
      Main switch / general protection
      ECP300 EXPERT STEPPER U VD 01
      4 poles magnetothermic 16A
      ECP300 EXPERT STEPPER U VD 02
      4 poles magnetothermic 25A
      Control
      ECP300 EXPERT STEPPER U VD 01
      Pego Stepper
      ECP300 EXPERT STEPPER U VD 02
      Pego Stepper
      Alarm signals
      ECP300 EXPERT STEPPER U VD 01
      Led + Buzzer
      ECP300 EXPERT STEPPER U VD 02
      Led + Buzzer
      Resolution
      ECP300 EXPERT STEPPER U VD 01
      0,1 °C
      ECP300 EXPERT STEPPER U VD 02
      -
      Ambient probe
      ECP300 EXPERT STEPPER U VD 01
      NTC 10 kΩ
      ECP300 EXPERT STEPPER U VD 02
      NTC 10 kΩ
      Evaporator probe 1
      ECP300 EXPERT STEPPER U VD 01
      NTC 10 kΩ
      ECP300 EXPERT STEPPER U VD 02
      NTC 10 kΩ
      Suction probe
      ECP300 EXPERT STEPPER U VD 01
      NTC 10 kΩ / PTC / PT1000
      ECP300 EXPERT STEPPER U VD 02
      NTC 10 kΩ / PTC / PT1000
      Evaporation pressure probe
      ECP300 EXPERT STEPPER U VD 01
      4-20 mA (not included)
      ECP300 EXPERT STEPPER U VD 02
      4-20 mA (not included)
      Door switch
      ECP300 EXPERT STEPPER U VD 01
      Present
      ECP300 EXPERT STEPPER U VD 02
      Present
      Man in cold-room alarm
      ECP300 EXPERT STEPPER U VD 01
      Available
      ECP300 EXPERT STEPPER U VD 02
      Available
      Defrosting heaters 1
      ECP300 EXPERT STEPPER U VD 01
      6000W (3 x 2000) Balanced resistive load
      ECP300 EXPERT STEPPER U VD 02
      "12000W (3 x 4000) Balanced resistive load"
      Evaporator fans
      ECP300 EXPERT STEPPER U VD 01
      1 x 1500W
      ECP300 EXPERT STEPPER U VD 02
      2 x 1500W
      Stepper valve output
      ECP300 EXPERT STEPPER U VD 01
      Bipolar
      ECP300 EXPERT STEPPER U VD 02
      Bipolar
      Enable condensing unit
      ECP300 EXPERT STEPPER U VD 01
      Present
      ECP300 EXPERT STEPPER U VD 02
      Present
      Room light
      ECP300 EXPERT STEPPER U VD 01
      Present
      ECP300 EXPERT STEPPER U VD 02
      Present
      Alarm/AUX relay
      ECP300 EXPERT STEPPER U VD 01
      Present
      ECP300 EXPERT STEPPER U VD 02
      Present
      Supervision
      ECP300 EXPERT STEPPER U VD 01
      TeleNet / Modbus-RTU
      ECP300 EXPERT STEPPER U VD 02
      TeleNet / Modbus-RTU
      Dimension
      ECP300 EXPERT STEPPER U VD 01
      ECP300 EXPERT STEPPER U VD
      ECP300 EXPERT STEPPER U VD 02
      ECP300 EXPERT STEPPER U VD
      Connection Scheme
      ECP300 EXPERT STEPPER U VD 01
      ECP300 EXPERT STEPPER U VD
      ECP300 EXPERT STEPPER U VD 02
      ECP300 EXPERT STEPPER U VD
      Technical Characteristics
      Inputs
      Outputs
      Dimensions and Diagram
      Available Versions
      ECP300 EXPERT STEPPER U VD 01
      ECP300 EXPERT STEPPER U VD 02
      Product Code
      11030ESUVD01
      Product Code
      11030ESUVD02
      Compressor
      Product Code
      11030ESUVD01
      No
      Evaporator fan
      Product Code
      11030ESUVD01
      1,5 kW
      Defrosting
      Product Code
      11030ESUVD01
      6,0 kW
      Electronic expansion valve
      Product Code
      11030ESUVD01
      Yes
      Man in cold-room alarm
      Product Code
      11030ESUVD01
      No
      Complete cold room management
      Product Code
      11030ESUVD01
      No
      Condensing unit management
      Product Code
      11030ESUVD01
      No
      Temperature/Humidity Management
      Product Code
      11030ESUVD01
      No
      Evaporating unit management
      Product Code
      11030ESUVD01
      Yes
      Double system management
      Product Code
      11030ESUVD01
      No
      Valve management electronic on/off
      Product Code
      11030ESUVD01
      No
      Valve management Stepper electronics
      Product Code
      11030ESUVD01
      Yes
      Double evaporator management
      Product Code
      11030ESUVD01
      No
      Datalogger
      Product Code
      11030ESUVD01
      No
      Compressor
      Product Code
      11030ESUVD02
      No
      Evaporator fan
      Product Code
      11030ESUVD02
      1,5 kW
      Defrosting
      Product Code
      11030ESUVD02
      12,0 kW
      Electronic expansion valve
      Product Code
      11030ESUVD02
      Yes
      Man in cold-room alarm
      Product Code
      11030ESUVD02
      No
      Complete cold room management
      Product Code
      11030ESUVD02
      No
      Condensing unit management
      Product Code
      11030ESUVD02
      No
      Temperature/Humidity Management
      Product Code
      11030ESUVD02
      No
      Evaporating unit management
      Product Code
      11030ESUVD02
      Yes
      Double system management
      Product Code
      11030ESUVD02
      No
      Valve management electronic on/off
      Product Code
      11030ESUVD02
      No
      Valve management Stepper electronics
      Product Code
      11030ESUVD02
      Yes
      Double evaporator management
      Product Code
      11030ESUVD02
      No
      Datalogger
      Product Code
      11030ESUVD02
      No

      Società soggetta all’attività di direzione
      e coordinamento di Castel S.r.l.

      P.I. 01071530297
      Capitale sociale € 100.000,00 i.v.
      Iscrizione Registro Imprese di Rovigo n.01071530297
      REA: 12439

      CONTACT

      Phone: (+39) 0425 762906

      E-Mail: info@pego.it

      Head Office: Via Piacentina, 6/b 45030, Occhiobello (RO)

      Seguici
      sui social

      Copyrights 2024 © Pego | Design and Bulding Teknet.it | Photography ad 3D Models TecnoMedia.biz