PRODUCTS | ELECTRICAL BOARDS
ECP300 EXPERT U VD
A LINE OF POWER AND ELECTRONIC CONTROL PANELS FOR CONTROL OF THE EVAPORATING UNIT ONLY
A line of power and control panels for refrigeration systems to control only the three-phase evaporating unit where units are served by a central refrigerator or remote condenser unit. Magnetothermic and differential protection for room light accessible from the front panel linked to an innovative form makes it a perfect and functional choice.
Available version with PULSE electronic valve integrated control.
Applications
-
Control of evaporating unit with electrical defrost up to 12 kW.
Main characteristics
- Enable for motor condenser unit, defrosting elements, evaporator fans, solenoid valve, room light and all standard-compliant electrical safeguards.
- Magnetothermic circuit breaker accessible from the front panel, which cuts the general power supply.
- Differential magnetothermic dedicated to room light accessible from the front panel (see the table).
- Easy wiring on the internal terminal block.
- Auxiliary relay with activation configurable by parameter.
- Transparent cover for access to all the protections, all with IP65 protection rating.
- Electronic control with wide LED display and easy to use buttons.
- Signaling with LED icons of the plant status.
- RS485 for connection to TeleNET industrial supervision network or Modbus-RTU standard protocol.
Properties
ECP 300 EXPERT U VD 6
ECP 300 EXPERT U VD 12
Dimension
ECP 300 EXPERT U VD 6
400 x 300 x 135 mm
ECP 300 EXPERT U VD 12
400 x 300 x 135 mm
Weight
ECP 300 EXPERT U VD 6
9kg
ECP 300 EXPERT U VD 12
10kg
Front protection rating
ECP 300 EXPERT U VD 6
IP 65
ECP 300 EXPERT U VD 12
IP 65
Power supply
ECP 300 EXPERT U VD 6
400 VAC ±10% 50/60 Hz
ECP 300 EXPERT U VD 12
400 VAC ±10% 50/60 Hz
Status indicator
ECP 300 EXPERT U VD 6
Led + Display
ECP 300 EXPERT U VD 12
Led + Display
Load type
ECP 300 EXPERT U VD 6
Three phase
ECP 300 EXPERT U VD 12
Three phase
Working temperature
ECP 300 EXPERT U VD 6
-5 ÷ +40°C
ECP 300 EXPERT U VD 12
-5 ÷ +40°C
Storage temperature
ECP 300 EXPERT U VD 6
-25 ÷ +55°C
ECP 300 EXPERT U VD 12
-25 ÷ +55°C
Relative ambient humidity
ECP 300 EXPERT U VD 6
30% - 90% RH without condensate
ECP 300 EXPERT U VD 12
30% - 90% RH without condensate
Reading range
ECP 300 EXPERT U VD 6
-45 ÷ +99°C
ECP 300 EXPERT U VD 12
-45 ÷ +99°C
Room light protection
ECP 300 EXPERT U VD 6
Differential magnetothermic circuit breaker (optional)
ECP 300 EXPERT U VD 12
Differential magnetothermic circuit breaker
Main switch / general protection
ECP 300 EXPERT U VD 6
4 poles magnetothermic 16A
ECP 300 EXPERT U VD 12
4 poles magnetothermic 25A
Control
ECP 300 EXPERT U VD 6
Pego
ECP 300 EXPERT U VD 12
Pego
Alarm signals
ECP 300 EXPERT U VD 6
Led + Buzzer
ECP 300 EXPERT U VD 12
Led + Buzzer
Defrosting
ECP 300 EXPERT U VD 6
Electrical
ECP 300 EXPERT U VD 12
Electrical
Resolution
ECP 300 EXPERT U VD 6
0,1 °C
ECP 300 EXPERT U VD 12
0,1 °C
Ambient probe
ECP 300 EXPERT U VD 6
NTC 10 kΩ
ECP 300 EXPERT U VD 12
NTC 10 kΩ
Evaporator probe 1
ECP 300 EXPERT U VD 6
NTC 10 kΩ
ECP 300 EXPERT U VD 12
NTC 10 kΩ
Door switch
ECP 300 EXPERT U VD 6
Present
ECP 300 EXPERT U VD 12
Present
Man in cold-room alarm
ECP 300 EXPERT U VD 6
Available
ECP 300 EXPERT U VD 12
Available
Defrosting heaters 1
ECP 300 EXPERT U VD 6
6000W (AC1) Eq. resistive load
ECP 300 EXPERT U VD 12
12000W (AC1) Eq. resistive load
Evaporator fans
ECP 300 EXPERT U VD 6
550W (1PH)
ECP 300 EXPERT U VD 12
2x2000W (3PH) or 2x1500W (1PH)
Solenoid valve
ECP 300 EXPERT U VD 6
Present
ECP 300 EXPERT U VD 12
Present
Door heater
ECP 300 EXPERT U VD 6
Present
ECP 300 EXPERT U VD 12
Present
Enable condensing unit
ECP 300 EXPERT U VD 6
Present
ECP 300 EXPERT U VD 12
Present
Room light
ECP 300 EXPERT U VD 6
800W (AC1) resistive load
ECP 300 EXPERT U VD 12
1200W (AC1) - Carico resistivo
2 Configurable relays
ECP 300 EXPERT U VD 6
Present
ECP 300 EXPERT U VD 12
Present
Supervision
ECP 300 EXPERT U VD 6
TeleNet / Modbus-RTU
ECP 300 EXPERT U VD 12
TeleNet / Modbus-RTU
Technical Characteristics
Inputs
Outputs
Dimensions and Diagram
Available Versions
ECP 300 EXPERT U VD 6
ECP 300 EXPERT U VD 12
Product Code
110300EUVD01
11030EEUVD01
Product Code
110300EUVD02
11030EEUVD02
Compressor
Product Code
110300EUVD01
110300EUVD01
No
Product Code
11030EEUVD01
11030EEUVD01
No
Evaporator fan
Product Code
110300EUVD01
110300EUVD01
0,55 kW
Product Code
11030EEUVD01
11030EEUVD01
0,55 kW
Defrosting
Product Code
110300EUVD01
110300EUVD01
6,0 kW
Product Code
11030EEUVD01
11030EEUVD01
6,0 kW
Electronic expansion valve
Product Code
110300EUVD01
110300EUVD01
No
Product Code
11030EEUVD01
11030EEUVD01
No
Man in cold-room alarm
Product Code
110300EUVD01
110300EUVD01
No
Product Code
11030EEUVD01
11030EEUVD01
No
Complete cold room management
Product Code
110300EUVD01
110300EUVD01
No
Product Code
11030EEUVD01
11030EEUVD01
No
Condensing unit management
Product Code
110300EUVD01
110300EUVD01
No
Product Code
11030EEUVD01
11030EEUVD01
No
Temperature/Humidity Management
Product Code
110300EUVD01
110300EUVD01
No
Product Code
11030EEUVD01
11030EEUVD01
No
Evaporating unit management
Product Code
110300EUVD01
110300EUVD01
Yes
Product Code
11030EEUVD01
11030EEUVD01
Yes
Double system management
Product Code
110300EUVD01
110300EUVD01
No
Product Code
11030EEUVD01
11030EEUVD01
No
Valve management electronic on/off
Product Code
110300EUVD01
110300EUVD01
No
Product Code
11030EEUVD01
11030EEUVD01
Yes
Valve management Stepper electronics
Product Code
110300EUVD01
110300EUVD01
No
Product Code
11030EEUVD01
11030EEUVD01
No
Double evaporator management
Product Code
110300EUVD01
110300EUVD01
No
Product Code
11030EEUVD01
11030EEUVD01
No
Datalogger
Product Code
110300EUVD01
110300EUVD01
No
Product Code
11030EEUVD01
11030EEUVD01
No
Compressor
Product Code
110300EUVD02
110300EUVD02
No
Product Code
11030EEUVD02
11030EEUVD02
No
Evaporator fan
Product Code
110300EUVD02
110300EUVD02
2,0 kW
Product Code
11030EEUVD02
11030EEUVD02
2,0 kW
Defrosting
Product Code
110300EUVD02
110300EUVD02
12,0 kW
Product Code
11030EEUVD02
11030EEUVD02
12,0 kW
Electronic expansion valve
Product Code
110300EUVD02
110300EUVD02
No
Product Code
11030EEUVD02
11030EEUVD02
No
Man in cold-room alarm
Product Code
110300EUVD02
110300EUVD02
No
Product Code
11030EEUVD02
11030EEUVD02
No
Complete cold room management
Product Code
110300EUVD02
110300EUVD02
No
Product Code
11030EEUVD02
11030EEUVD02
No
Condensing unit management
Product Code
110300EUVD02
110300EUVD02
No
Product Code
11030EEUVD02
11030EEUVD02
No
Temperature/Humidity Management
Product Code
110300EUVD02
110300EUVD02
No
Product Code
11030EEUVD02
11030EEUVD02
No
Evaporating unit management
Product Code
110300EUVD02
110300EUVD02
Yes
Product Code
11030EEUVD02
11030EEUVD02
Yes
Double system management
Product Code
110300EUVD02
110300EUVD02
No
Product Code
11030EEUVD02
11030EEUVD02
No
Valve management electronic on/off
Product Code
110300EUVD02
110300EUVD02
No
Product Code
11030EEUVD02
11030EEUVD02
Yes
Valve management Stepper electronics
Product Code
110300EUVD02
110300EUVD02
No
Product Code
11030EEUVD02
11030EEUVD02
No
Double evaporator management
Product Code
110300EUVD02
110300EUVD02
No
Product Code
11030EEUVD02
11030EEUVD02
No
Datalogger
Product Code
110300EUVD02
110300EUVD02
No
Product Code
11030EEUVD02
11030EEUVD02
No