PRODUCTS | ELECTRICAL BOARDS
HYPERANGE 030 B6 VEH-1 / VEH-2
A LINE OF CONTROL PANELS FOR COLD ROOMS
Power and control panel line for refrigeration systems with three-phase compressor up to 10 HP designed for the complete management of the cold room. The different power ranges combined with the simplicity of configuring the operating modes allow the creation of an ad hoc panel for the system. The electronic thermal protections make the panel extremely versatile.
Applications
-
Complete management of static or ventilated three-phase refrigeration systems up to 10 HP, with off cycle, electric or hot gas defrost, with compressor management with thermostat or pump-down pressure switch
Main characteristics
- Direct management of the compressor, condenser fans, compressor oil heater, defrost heaters, evaporator fans, solenoid valve, cold room light and all the electrical protections required by the regulations
- Configurable hot gas defrost management
- Configurable pump-down compressor stop management
- Anti-condensation door heater control
- Electronic thermal protections for the compressor, for greater versatility
- Configurable digital inputs and outputs
- Compact panel in self-extinguishing ABS with IP65 protection rating and selector switch on the front of the panel
- Control electronics with large LED display and user-friendly keyboard
- System status indication with LED icons
- RS485 for connection to the TeleNET industrial supervision network or Modbus-RTU standard protocol
Properties
HYP030VE001
HYP030VE002
HYP075VE001
HYP0100VE001
Dimension
HYP030VE001
290 x 340 x 145 mm
HYP030VE002
290 x 340 x 145 mm
HYP075VE001
-
HYP0100VE001
-
Weight
HYP030VE001
5kg
HYP030VE002
6kg
HYP075VE001
-
HYP0100VE001
-
Front protection rating
HYP030VE001
IP 65
HYP030VE002
IP 65
HYP075VE001
-
HYP0100VE001
-
Power supply
HYP030VE001
400 VAC ±10% 50/60 Hz
HYP030VE002
400 VAC ±10% 50/60 Hz
HYP075VE001
-
HYP0100VE001
-
Status indicator
HYP030VE001
Led + Display
HYP030VE002
Led + Display
HYP075VE001
-
HYP0100VE001
-
Load type
HYP030VE001
Three phase
HYP030VE002
Three phase
HYP075VE001
-
HYP0100VE001
-
Working temperature
HYP030VE001
-5 ÷ +40°C
HYP030VE002
-5 ÷ +40°C
HYP075VE001
-
HYP0100VE001
-
Storage temperature
HYP030VE001
-10 ÷ +70°C
HYP030VE002
-10 ÷ +70 °C
HYP075VE001
-
HYP0100VE001
-
Relative ambient humidity
HYP030VE001
30% - 90% RH without condensate
HYP030VE002
30% - 90% RH without condensate
HYP075VE001
-
HYP0100VE001
-
Reading range
HYP030VE001
-45 ÷ +99°C
HYP030VE002
-45 ÷ +99°C
HYP075VE001
-
HYP0100VE001
-
Door lock main switch
HYP030VE001
16 A
HYP030VE002
25 A
HYP075VE001
-
HYP0100VE001
-
Compressor protection
HYP030VE001
Electronic thermal relay
HYP030VE002
Electronic thermal relay
HYP075VE001
-
HYP0100VE001
-
General protection
HYP030VE001
Magnetothermal switches
HYP030VE002
Magnetothermal switches
HYP075VE001
-
HYP0100VE001
-
Control
HYP030VE001
Pego
HYP030VE002
Pego
HYP075VE001
-
HYP0100VE001
-
Alarm signals
HYP030VE001
Led + Buzzer
HYP030VE002
Led + Buzzer
HYP075VE001
-
HYP0100VE001
-
Defrosting
HYP030VE001
Electrical
HYP030VE002
Electrical
HYP075VE001
-
HYP0100VE001
-
Insulation transformer
HYP030VE001
Present
HYP030VE002
Present
HYP075VE001
-
HYP0100VE001
-
Ambient probe
HYP030VE001
NTC 10 kΩ
HYP030VE002
NTC 10 kΩ
HYP075VE001
-
HYP0100VE001
-
Evaporator probe
HYP030VE001
NTC 10 kΩ
HYP030VE002
NTC 10 kΩ
HYP075VE001
-
HYP0100VE001
-
Door switch
HYP030VE001
Present
HYP030VE002
Present
HYP075VE001
-
HYP0100VE001
-
High/low pressure switch
HYP030VE001
Present
HYP030VE002
Present
HYP075VE001
-
HYP0100VE001
-
Pump down pressure switch
HYP030VE001
Present
HYP030VE002
Present
HYP075VE001
-
HYP0100VE001
-
Kriwan® connection
HYP030VE001
Present
HYP030VE002
Present
HYP075VE001
-
HYP0100VE001
-
Compressor
HYP030VE001
Max 4 A
HYP030VE002
Max 12 A
HYP075VE001
-
HYP0100VE001
-
Defrosting
HYP030VE001
4500W (AC1)
HYP030VE002
-
HYP075VE001
-
HYP0100VE001
-
Evaporator fans
HYP030VE001
750W (1HP)
HYP030VE002
750W (1HP)
HYP075VE001
-
HYP0100VE001
-
Condenser fans output 1
HYP030VE001
500W (1HP)
HYP030VE002
500W (1HP)
HYP075VE001
-
HYP0100VE001
-
Solenoid valve
HYP030VE001
Present
HYP030VE002
Present
HYP075VE001
-
HYP0100VE001
-
Solenoide gas caldo
HYP030VE001
-
HYP030VE002
Present
HYP075VE001
-
HYP0100VE001
-
Compressor oil heater
HYP030VE001
Present
HYP030VE002
Present
HYP075VE001
-
HYP0100VE001
-
Door heater
HYP030VE001
Present
HYP030VE002
Present
HYP075VE001
-
HYP0100VE001
-
Room light
HYP030VE001
Present
HYP030VE002
Present
HYP075VE001
-
HYP0100VE001
-
Alarm/AUX relay
HYP030VE001
Present
HYP030VE002
Present
HYP075VE001
-
HYP0100VE001
-
Supervision
HYP030VE001
TeleNet / Modbus-RTU
HYP030VE002
TeleNet / Modbus-RTU
HYP075VE001
-
HYP0100VE001
-
Technical Characteristics
Inputs
Outputs
Dimensions and Diagram
Available Versions
HYP030VE001
HYP030VE002
HYP075VE001
HYP0100VE001
Product Code
HYP030VE001
Product Code
HYP030VE002
Product Code
HYP075VE001
Product Code
HYP100VE001
Compressor
Product Code
HYP030VE001
HYP030VE001
1 - 4 A
Evaporator fan
HYP030VE001
-
Defrosting
Product Code
HYP030VE001
HYP030VE001
4,5 kw
Electronic expansion valve
Product Code
HYP030VE001
HYP030VE001
No
Man in cold-room alarm
Product Code
HYP030VE001
HYP030VE001
No
Complete cold room management
Product Code
HYP030VE001
HYP030VE001
Yes
Condensing unit management
Product Code
HYP030VE001
HYP030VE001
No
Temperature/Humidity Management
Product Code
HYP030VE001
HYP030VE001
No
Evaporating unit management
Product Code
HYP030VE001
HYP030VE001
No
Double system management
Product Code
HYP030VE001
HYP030VE001
No
Valve management electronic on/off
Product Code
HYP030VE001
HYP030VE001
No
Valve management Stepper electronics
Product Code
HYP030VE001
HYP030VE001
No
Double evaporator management
Product Code
HYP030VE001
HYP030VE001
No
Datalogger
Product Code
HYP030VE001
HYP030VE001
No
Compressor
HYP030VE002
-
Evaporator fan
HYP030VE002
-
Defrosting
Product Code
HYP030VE002
HYP030VE002
7,5 kW
Electronic expansion valve
Product Code
HYP030VE002
HYP030VE002
No
Man in cold-room alarm
Product Code
HYP030VE002
HYP030VE002
No
Complete cold room management
Product Code
HYP030VE002
HYP030VE002
Yes
Condensing unit management
Product Code
HYP030VE002
HYP030VE002
No
Temperature/Humidity Management
Product Code
HYP030VE002
HYP030VE002
No
Evaporating unit management
Product Code
HYP030VE002
HYP030VE002
No
Double system management
Product Code
HYP030VE002
HYP030VE002
No
Valve management electronic on/off
Product Code
HYP030VE002
HYP030VE002
No
Valve management Stepper electronics
Product Code
HYP030VE002
HYP030VE002
No
Double evaporator management
Product Code
HYP030VE002
HYP030VE002
No
Datalogger
Product Code
HYP030VE002
HYP030VE002
No
Compressor
Product Code
HYP075VE001
HYP075VE001
4 - 16 A
Evaporator fan
Product Code
HYP075VE001
HYP075VE001
1,1 kW
Defrosting
Product Code
HYP075VE001
HYP075VE001
10,5 kW
Electronic expansion valve
Product Code
HYP075VE001
HYP075VE001
No
Man in cold-room alarm
Product Code
HYP075VE001
HYP075VE001
No
Complete cold room management
Product Code
HYP075VE001
HYP075VE001
Yes
Condensing unit management
Product Code
HYP075VE001
HYP075VE001
No
Temperature/Humidity Management
Product Code
HYP075VE001
HYP075VE001
No
Evaporating unit management
Product Code
HYP075VE001
HYP075VE001
No
Double system management
Product Code
HYP075VE001
HYP075VE001
No
Valve management electronic on/off
Product Code
HYP075VE001
HYP075VE001
No
Valve management Stepper electronics
Product Code
HYP075VE001
HYP075VE001
No
Double evaporator management
Product Code
HYP075VE001
HYP075VE001
No
Datalogger
Product Code
HYP075VE001
HYP075VE001
No
Compressor
Product Code
HYP100VE001
HYP100VE001
6 - 25 A
Evaporator fan
Product Code
HYP100VE001
HYP100VE001
1,5 kW
Defrosting
Product Code
HYP100VE001
HYP100VE001
15,0 kw
Electronic expansion valve
Product Code
HYP100VE001
HYP100VE001
No
Man in cold-room alarm
Product Code
HYP100VE001
HYP100VE001
No
Complete cold room management
Product Code
HYP100VE001
HYP100VE001
Yes
Condensing unit management
Product Code
HYP100VE001
HYP100VE001
No
Temperature/Humidity Management
Product Code
HYP100VE001
HYP100VE001
No
Evaporating unit management
Product Code
HYP100VE001
HYP100VE001
No
Double system management
Product Code
HYP100VE001
HYP100VE001
No
Valve management electronic on/off
Product Code
HYP100VE001
HYP100VE001
No
Valve management Stepper electronics
Product Code
HYP100VE001
HYP100VE001
No
Double evaporator management
Product Code
HYP100VE001
HYP100VE001
No
Datalogger
Product Code
HYP100VE001
HYP100VE001
No