PRODUCTS | ELECTRICAL BOARDS
HYPERANGE 030 B6 VEH-1 / VEH-2
A LINE OF CONTROL PANELS FOR COLD ROOMS
Power and control panel line for refrigeration systems with three-phase compressor up to 10 HP designed for the complete management of the cold room. The different power ranges combined with the simplicity of configuring the operating modes allow the creation of an ad hoc panel for the system. The electronic thermal protections make the panel extremely versatile.
Applications
-
Complete management of static or ventilated three-phase refrigeration systems up to 10 HP, with off cycle, electric or hot gas defrost, with compressor management with thermostat or pump-down pressure switch
Main characteristics
- Direct management of the compressor, condenser fans, compressor oil heater, defrost heaters, evaporator fans, solenoid valve, cold room light and all the electrical protections required by the regulations
- Configurable hot gas defrost management
- Configurable pump-down compressor stop management
- Anti-condensation door heater control
- Electronic thermal protections for the compressor, for greater versatility
- Configurable digital inputs and outputs
- Compact panel in self-extinguishing ABS with IP65 protection rating and selector switch on the front of the panel
- Control electronics with large LED display and user-friendly keyboard
- System status indication with LED icons
- RS485 for connection to the TeleNET industrial supervision network or Modbus-RTU standard protocol
Properties
HYPERANGE 030 B6 VEH-1
HYPERANGE 030 B6 VEH-2
Dimension
HYPERANGE 030 B6 VEH-1
290 x 340 x 145 mm
HYPERANGE 030 B6 VEH-2
290 x 340 x 145 mm
Weight
HYPERANGE 030 B6 VEH-1
5kg
HYPERANGE 030 B6 VEH-2
6kg
Front protection rating
HYPERANGE 030 B6 VEH-1
IP 65
HYPERANGE 030 B6 VEH-2
IP 65
Power supply
HYPERANGE 030 B6 VEH-1
400 VAC ±10% 50/60 Hz
HYPERANGE 030 B6 VEH-2
400 VAC ±10% 50/60 Hz
Status indicator
HYPERANGE 030 B6 VEH-1
Led + Display
HYPERANGE 030 B6 VEH-2
Led + Display
Load type
HYPERANGE 030 B6 VEH-1
Three phase
HYPERANGE 030 B6 VEH-2
Three phase
Working temperature
HYPERANGE 030 B6 VEH-1
-5 ÷ +40°C
HYPERANGE 030 B6 VEH-2
-5 ÷ +40°C
Storage temperature
HYPERANGE 030 B6 VEH-1
-10 ÷ +70°C
HYPERANGE 030 B6 VEH-2
-10 ÷ +70 °C
Relative ambient humidity
HYPERANGE 030 B6 VEH-1
30% - 90% RH without condensate
HYPERANGE 030 B6 VEH-2
30% - 90% RH without condensate
Reading range
HYPERANGE 030 B6 VEH-1
-45 ÷ +99°C
HYPERANGE 030 B6 VEH-2
-45 ÷ +99°C
Door lock main switch
HYPERANGE 030 B6 VEH-1
16 A
HYPERANGE 030 B6 VEH-2
25 A
Compressor protection
HYPERANGE 030 B6 VEH-1
Electronic thermal relay
HYPERANGE 030 B6 VEH-2
Electronic thermal relay
General protection
HYPERANGE 030 B6 VEH-1
Magnetothermal switches
HYPERANGE 030 B6 VEH-2
Magnetothermal switches
Control
HYPERANGE 030 B6 VEH-1
Pego
HYPERANGE 030 B6 VEH-2
Pego
Alarm signals
HYPERANGE 030 B6 VEH-1
Led + Buzzer
HYPERANGE 030 B6 VEH-2
Led + Buzzer
Defrosting
HYPERANGE 030 B6 VEH-1
Electric / Hot gas
HYPERANGE 030 B6 VEH-2
Electric / Hot gas
Insulation transformer
HYPERANGE 030 B6 VEH-1
Present
HYPERANGE 030 B6 VEH-2
Present
Ambient probe
HYPERANGE 030 B6 VEH-1
NTC 10 kΩ
HYPERANGE 030 B6 VEH-2
NTC 10 kΩ
Evaporator probe
HYPERANGE 030 B6 VEH-1
NTC 10 kΩ
HYPERANGE 030 B6 VEH-2
NTC 10 kΩ
Door switch
HYPERANGE 030 B6 VEH-1
Present
HYPERANGE 030 B6 VEH-2
Present
High/low pressure switch
HYPERANGE 030 B6 VEH-1
Present
HYPERANGE 030 B6 VEH-2
Present
Pump down pressure switch
HYPERANGE 030 B6 VEH-1
Present
HYPERANGE 030 B6 VEH-2
Present
Kriwan® connection
HYPERANGE 030 B6 VEH-1
Present
HYPERANGE 030 B6 VEH-2
Present
Compressor
HYPERANGE 030 B6 VEH-1
Max 4 A
HYPERANGE 030 B6 VEH-2
Max 12 A
Defrosting
HYPERANGE 030 B6 VEH-1
4500W (AC1)
HYPERANGE 030 B6 VEH-2
-
Evaporator fans
HYPERANGE 030 B6 VEH-1
750W (1HP)
HYPERANGE 030 B6 VEH-2
750W (1HP)
Condenser fans output 1
HYPERANGE 030 B6 VEH-1
500W (1HP)
HYPERANGE 030 B6 VEH-2
500W (1HP)
Solenoid valve
HYPERANGE 030 B6 VEH-1
Present
HYPERANGE 030 B6 VEH-2
Present
Solenoide gas caldo
HYPERANGE 030 B6 VEH-1
Present
HYPERANGE 030 B6 VEH-2
Present
Compressor oil heater
HYPERANGE 030 B6 VEH-1
Present
HYPERANGE 030 B6 VEH-2
Present
Door heater
HYPERANGE 030 B6 VEH-1
Present
HYPERANGE 030 B6 VEH-2
Present
Room light
HYPERANGE 030 B6 VEH-1
Present
HYPERANGE 030 B6 VEH-2
Present
Alarm/AUX relay
HYPERANGE 030 B6 VEH-1
Present
HYPERANGE 030 B6 VEH-2
Present
Supervision
HYPERANGE 030 B6 VEH-1
TeleNet / Modbus-RTU
HYPERANGE 030 B6 VEH-2
TeleNet / Modbus-RTU
Technical Characteristics
Inputs
Outputs
Dimensions and Diagram
Available Versions
HYPERANGE 030 B6 VEH-1
HYPERANGE 030 B6 VEH-2
Product Code
110030B6VEH0001
110030B6VEHA001
Product Code
110030B6VEH0002
110030B6VEHA002
Compressor
Product Code
110030B6VEH0001
110030B6VEH0001
1 - 4 A
Product Code
110030B6VEHA001
110030B6VEHA001
2 - 6.3 A
Evaporator fan
Product Code
110030B6VEH0001
110030B6VEH0001
1,5 kW
Product Code
110030B6VEHA001
110030B6VEHA001
1,5 kW
Defrosting
Product Code
110030B6VEH0001
110030B6VEH0001
7,5 kW
Product Code
110030B6VEHA001
110030B6VEHA001
7,5 kW
Electronic expansion valve
Product Code
110030B6VEH0001
110030B6VEH0001
No
Product Code
110030B6VEHA001
110030B6VEHA001
No
Man in cold-room alarm
Product Code
110030B6VEH0001
110030B6VEH0001
No
Product Code
110030B6VEHA001
110030B6VEHA001
No
Complete cold room management
Product Code
110030B6VEH0001
110030B6VEH0001
Yes
Product Code
110030B6VEHA001
110030B6VEHA001
Yes
Condensing unit management
Product Code
110030B6VEH0001
110030B6VEH0001
No
Product Code
110030B6VEHA001
110030B6VEHA001
No
Temperature/Humidity Management
Product Code
110030B6VEH0001
110030B6VEH0001
No
Product Code
110030B6VEHA001
110030B6VEHA001
No
Evaporating unit management
Product Code
110030B6VEH0001
110030B6VEH0001
No
Product Code
110030B6VEHA001
110030B6VEHA001
No
Double system management
Product Code
110030B6VEH0001
110030B6VEH0001
No
Product Code
110030B6VEHA001
110030B6VEHA001
No
Valve management electronic on/off
Product Code
110030B6VEH0001
110030B6VEH0001
No
Product Code
110030B6VEHA001
110030B6VEHA001
No
Valve management Stepper electronics
Product Code
110030B6VEH0001
110030B6VEH0001
No
Product Code
110030B6VEHA001
110030B6VEHA001
No
Double evaporator management
Product Code
110030B6VEH0001
110030B6VEH0001
No
Product Code
110030B6VEHA001
110030B6VEHA001
No
Datalogger
Product Code
110030B6VEH0001
110030B6VEH0001
No
Product Code
110030B6VEHA001
110030B6VEHA001
No
Compressor
Product Code
110030B6VEH0002
110030B6VEH0002
1 - 4 A
Product Code
110030B6VEHA002
110030B6VEHA002
5.7 - 12 A
Evaporator fan
Product Code
110030B6VEH0002
110030B6VEH0002
1,5 kW
Product Code
110030B6VEHA002
110030B6VEHA002
1,5 kW
Defrosting
Product Code
110030B6VEH0002
110030B6VEH0002
7,5 kW
Product Code
110030B6VEHA002
110030B6VEHA002
7,5 kW
Electronic expansion valve
Product Code
110030B6VEH0002
110030B6VEH0002
No
Product Code
110030B6VEHA002
110030B6VEHA002
No
Man in cold-room alarm
Product Code
110030B6VEH0002
110030B6VEH0002
No
Product Code
110030B6VEHA002
110030B6VEHA002
No
Complete cold room management
Product Code
110030B6VEH0002
110030B6VEH0002
Yes
Product Code
110030B6VEHA002
110030B6VEHA002
Yes
Condensing unit management
Product Code
110030B6VEH0002
110030B6VEH0002
No
Product Code
110030B6VEHA002
110030B6VEHA002
No
Temperature/Humidity Management
Product Code
110030B6VEH0002
110030B6VEH0002
No
Product Code
110030B6VEHA002
110030B6VEHA002
No
Evaporating unit management
Product Code
110030B6VEH0002
110030B6VEH0002
No
Product Code
110030B6VEHA002
110030B6VEHA002
No
Double system management
Product Code
110030B6VEH0002
110030B6VEH0002
No
Product Code
110030B6VEHA002
110030B6VEHA002
No
Valve management electronic on/off
Product Code
110030B6VEH0002
110030B6VEH0002
No
Product Code
110030B6VEHA002
110030B6VEHA002
No
Valve management Stepper electronics
Product Code
110030B6VEH0002
110030B6VEH0002
No
Product Code
110030B6VEHA002
110030B6VEHA002
No
Double evaporator management
Product Code
110030B6VEH0002
110030B6VEH0002
No
Product Code
110030B6VEHA002
110030B6VEHA002
No
Datalogger
Product Code
110030B6VEH0002
110030B6VEH0002
No
Product Code
110030B6VEHA002
110030B6VEHA002
No