Skip to main content
PRODUCTS | ELECTRICAL BOARDS
HYPERANGE 075 / 100 B6 VEH

A LINE OF CONTROL PANELS FOR COLD ROOMS

A LINE OF CONTROL PANELS FOR COLD ROOMS

    Power and control panel line for refrigeration systems with three-phase compressor up to 10 HP designed for the complete management of the cold room. The different power ranges combined with the simplicity of configuring the operating modes allow the creation of an ad hoc panel for the system. The electronic thermal protections make the panel extremely versatile.

    A LINE OF CONTROL PANELS FOR COLD ROOMS
      Applications
      • Complete management of static or ventilated three-phase refrigeration systems up to 10 HP, with off cycle, electric or hot gas defrost, with compressor management with thermostat or pump-down pressure switch

      Main characteristics
      • Direct management of the compressor, condenser fans, compressor oil heater, defrost heaters, evaporator fans, solenoid valve, cold room light and all the electrical protections required by the regulations
      • Configurable hot gas defrost management
      • Configurable pump-down compressor stop management
      • Anti-condensation door heater control
      • Electronic thermal protections for the compressor, for greater versatility
      • Configurable digital inputs and outputs
      • Compact panel in self-extinguishing ABS with IP65 protection rating and selector switch on the front of the panel
      • Control electronics with large LED display and user-friendly keyboard
      • System status indication with LED icons
      • RS485 for connection to the TeleNET industrial supervision network or Modbus-RTU standard protocol
      Properties
       
      HYPERANGE 075 B6 VEH
      HYPERANGE 100 B6 VEH
      Dimension
      HYPERANGE 075 B6 VEH
      350 x 450 x 160 mm
      HYPERANGE 100 B6 VEH
      350 x 450 x 160 mm
      Weight
      HYPERANGE 075 B6 VEH
      6kg
      HYPERANGE 100 B6 VEH
      7kg
      Front protection rating
      HYPERANGE 075 B6 VEH
      IP 65
      HYPERANGE 100 B6 VEH
      IP 65
      Power supply
      HYPERANGE 075 B6 VEH
      400 VAC ±10% 50/60 Hz
      HYPERANGE 100 B6 VEH
      400 VAC ±10% 50/60 Hz
      Status indicator
      HYPERANGE 075 B6 VEH
      Led + Display
      HYPERANGE 100 B6 VEH
      Led + Display
      Load type
      HYPERANGE 075 B6 VEH
      Three phase
      HYPERANGE 100 B6 VEH
      Three phase
      Working temperature
      HYPERANGE 075 B6 VEH
      -5 ÷ +40°C
      HYPERANGE 100 B6 VEH
      -5 ÷ +40°C
      Storage temperature
      HYPERANGE 075 B6 VEH
      -10 ÷ +70 °C
      HYPERANGE 100 B6 VEH
      -10 ÷ +70°C
      Relative ambient humidity
      HYPERANGE 075 B6 VEH
      30% - 90% RH without condensate
      HYPERANGE 100 B6 VEH
      30% - 90% RH without condensate
      Reading range
      HYPERANGE 075 B6 VEH
      -45 ÷ +99°C
      HYPERANGE 100 B6 VEH
      -45 ÷ +99°C
      Door lock main switch
      HYPERANGE 075 B6 VEH
      40 A
      HYPERANGE 100 B6 VEH
      63 A
      Compressor protection
      HYPERANGE 075 B6 VEH
      Electronic thermal relay
      HYPERANGE 100 B6 VEH
      Electronic thermal relay
      General protection
      HYPERANGE 075 B6 VEH
      Magnetothermal switches
      HYPERANGE 100 B6 VEH
      Magnetothermal switches
      Control
      HYPERANGE 075 B6 VEH
      Pego
      HYPERANGE 100 B6 VEH
      Pego
      Alarm signals
      HYPERANGE 075 B6 VEH
      Led + Buzzer
      HYPERANGE 100 B6 VEH
      Led + Buzzer
      Defrosting
      HYPERANGE 075 B6 VEH
      Electric / Hot gas
      HYPERANGE 100 B6 VEH
      Electric / Hot gas
      Insulation transformer
      HYPERANGE 075 B6 VEH
      Present
      HYPERANGE 100 B6 VEH
      Present
      Ambient probe
      HYPERANGE 075 B6 VEH
      NTC 10 kΩ
      HYPERANGE 100 B6 VEH
      NTC 10 kΩ
      Evaporator probe
      HYPERANGE 075 B6 VEH
      NTC 10 kΩ
      HYPERANGE 100 B6 VEH
      NTC 10 kΩ
      Door switch
      HYPERANGE 075 B6 VEH
      Present
      HYPERANGE 100 B6 VEH
      Present
      High/low pressure switch
      HYPERANGE 075 B6 VEH
      Present
      HYPERANGE 100 B6 VEH
      Present
      Pump down pressure switch
      HYPERANGE 075 B6 VEH
      Present
      HYPERANGE 100 B6 VEH
      Present
      Kriwan® connection
      HYPERANGE 075 B6 VEH
      Present
      HYPERANGE 100 B6 VEH
      Present
      Compressor
      HYPERANGE 075 B6 VEH
      Max 16 A
      HYPERANGE 100 B6 VEH
      Max 25 A
      Defrosting
      HYPERANGE 075 B6 VEH
      10500W (AC1)
      HYPERANGE 100 B6 VEH
      15000W (AC1)
      Evaporator fans
      HYPERANGE 075 B6 VEH
      1100W (1PH)
      HYPERANGE 100 B6 VEH
      1500W ( 3PH / 1PH )
      Condenser fans output 1
      HYPERANGE 075 B6 VEH
      800W (1PH)
      HYPERANGE 100 B6 VEH
      1500W (3HP / 1PH)
      Condenser fans output 2
      HYPERANGE 075 B6 VEH
      800W ( 1PH )
      HYPERANGE 100 B6 VEH
      1500W ( 3PH / 1PH )
      Solenoid valve
      HYPERANGE 075 B6 VEH
      Present
      HYPERANGE 100 B6 VEH
      Present
      Solenoide gas caldo
      HYPERANGE 075 B6 VEH
      Present
      HYPERANGE 100 B6 VEH
      Present
      Compressor oil heater
      HYPERANGE 075 B6 VEH
      Present
      HYPERANGE 100 B6 VEH
      Present
      Door heater
      HYPERANGE 075 B6 VEH
      Present
      HYPERANGE 100 B6 VEH
      Present
      Room light
      HYPERANGE 075 B6 VEH
      Present
      HYPERANGE 100 B6 VEH
      Present
      Alarm/AUX relay
      HYPERANGE 075 B6 VEH
      Present
      HYPERANGE 100 B6 VEH
      Present
      Supervision
      HYPERANGE 075 B6 VEH
      TeleNet / Modbus-RTU
      HYPERANGE 100 B6 VEH
      TeleNet / Modbus-RTU
      Dimension
      HYPERANGE 075 B6 VEH
      HYPERANGE 075 / 100 B6 VEH
      HYPERANGE 100 B6 VEH
      HYPERANGE 075 / 100 B6 VEH
      Connection Scheme
      HYPERANGE 075 B6 VEH
      HYPERANGE 075 / 100 B6 VEH
      HYPERANGE 100 B6 VEH
      HYPERANGE 075 / 100 B6 VEH
      Technical Characteristics
      Inputs
      Outputs
      Dimensions and Diagram
      Available Versions
      HYPERANGE 075 B6 VEH
      HYPERANGE 100 B6 VEH
      Product Code
      110075B6VEH0001
      110075B6VEHA001
      Product Code
      110100B6VEH0001
      110100B6VEHA001
      Compressor
      Product Code
      110075B6VEH0001
      4 - 16 A
      Product Code
      110075B6VEHA001
      5.7 - 18 A
      Evaporator fan
      Product Code
      110075B6VEH0001
      1,1 kW
      Product Code
      110075B6VEHA001
      1,1 kW
      Defrosting
      Product Code
      110075B6VEH0001
      10,5 kW
      Product Code
      110075B6VEHA001
      10,5 kW
      Electronic expansion valve
      Product Code
      110075B6VEH0001
      No
      Product Code
      110075B6VEHA001
      No
      Man in cold-room alarm
      Product Code
      110075B6VEH0001
      No
      Product Code
      110075B6VEHA001
      No
      Complete cold room management
      Product Code
      110075B6VEH0001
      Yes
      Product Code
      110075B6VEHA001
      Yes
      Condensing unit management
      Product Code
      110075B6VEH0001
      No
      Product Code
      110075B6VEHA001
      No
      Temperature/Humidity Management
      Product Code
      110075B6VEH0001
      No
      Product Code
      110075B6VEHA001
      No
      Evaporating unit management
      Product Code
      110075B6VEH0001
      No
      Product Code
      110075B6VEHA001
      No
      Double system management
      Product Code
      110075B6VEH0001
      No
      Product Code
      110075B6VEHA001
      No
      Valve management electronic on/off
      Product Code
      110075B6VEH0001
      No
      Product Code
      110075B6VEHA001
      No
      Valve management Stepper electronics
      Product Code
      110075B6VEH0001
      No
      Product Code
      110075B6VEHA001
      No
      Double evaporator management
      Product Code
      110075B6VEH0001
      No
      Product Code
      110075B6VEHA001
      No
      Datalogger
      Product Code
      110075B6VEH0001
      No
      Product Code
      110075B6VEHA001
      No
      Compressor
      Product Code
      110100B6VEH0001
      6 - 25 A
      Product Code
      110100B6VEHA001
      9 - 25 A
      Evaporator fan
      Product Code
      110100B6VEH0001
      1,5 kW
      Product Code
      110100B6VEHA001
      1,5 kW
      Defrosting
      Product Code
      110100B6VEH0001
      15,0 kw
      Product Code
      110100B6VEHA001
      15,0 kw
      Electronic expansion valve
      Product Code
      110100B6VEH0001
      No
      Product Code
      110100B6VEHA001
      No
      Man in cold-room alarm
      Product Code
      110100B6VEH0001
      No
      Product Code
      110100B6VEHA001
      No
      Complete cold room management
      Product Code
      110100B6VEH0001
      Yes
      Product Code
      110100B6VEHA001
      Yes
      Condensing unit management
      Product Code
      110100B6VEH0001
      No
      Product Code
      110100B6VEHA001
      No
      Temperature/Humidity Management
      Product Code
      110100B6VEH0001
      No
      Product Code
      110100B6VEHA001
      No
      Evaporating unit management
      Product Code
      110100B6VEH0001
      No
      Product Code
      110100B6VEHA001
      No
      Double system management
      Product Code
      110100B6VEH0001
      No
      Product Code
      110100B6VEHA001
      No
      Valve management electronic on/off
      Product Code
      110100B6VEH0001
      No
      Product Code
      110100B6VEHA001
      No
      Valve management Stepper electronics
      Product Code
      110100B6VEH0001
      No
      Product Code
      110100B6VEHA001
      No
      Double evaporator management
      Product Code
      110100B6VEH0001
      No
      Product Code
      110100B6VEHA001
      No
      Datalogger
      Product Code
      110100B6VEH0001
      No
      Product Code
      110100B6VEHA001
      No

      Società soggetta all’attività di direzione
      e coordinamento di Castel S.r.l.

      P.I. 01071530297
      Capitale sociale € 100.000,00 i.v.
      Iscrizione Registro Imprese di Rovigo n.01071530297
      REA: 12439

      CONTACT

      Phone: (+39) 0425 762906

      E-Mail: info@pego.it

      Head Office: Via Piacentina, 6/b 45030, Occhiobello (RO)

      Seguici
      sui social

      Copyrights 2024 © Pego | Design and Bulding Teknet.it | Photography ad 3D Models TecnoMedia.biz