PRODUCTS | ELECTRICAL BOARDS
NANO 04 VD
A LINE OF POWER AND CONTROL BOARDS FOR REFRIGERATION SYSTEM
A line of power and control boards for refrigeration systems with three-phase compressors up to 2,5 HP that provide complete cold room management. You can control the room light and the stand-by system using the buttons on the thermostat. Integrated PEGO thermo-regulator controls compressor, ventilation, defrosting and light. The unit also controls the door switch, which automatically turns on the room light, and compressor and fan shutdown.
Applications
-
Complete control of three-phase static or ventilated refrigeration systems up to 2,5 HP, with electric or off-cycle defrost.
Main characteristic
- Designed to provide an immediate start-up and easy maintenance.
- Direct control of compressor, condenser fans, compressor oil element, defrost elements, evaporator fans, solenoid valve, room light and all standard-compliant electrical safeguards.
- Compact unit with self-extinguishing ABS housing panel and IP55 protection rating plus circuit breaker on front of panel.
- Integrated PEGO thermo-regulator (Expert Nano 4CK).
- System status indicated by display.
- Key operated ON/OFF.
- Cold room light ON/OFF switch with key or by means of door switch.
- Key operated manual START/STOP defrosting.
- Clock for programmed defrost (RTC).
- Configurable multifunction output, alternative to the light output.
- RS485 serial connection with Modbus-RTU or Telenet protocol.
Properties
Dimension
NANO 04 VD
210x260x145 mm
Weight
NANO 04 VD
4kg
Front protection rating
NANO 04 VD
IP 55
Power supply
NANO 04 VD
400 VAC ±10% 50/60 Hz
Status indicator
NANO 04 VD
Display
Load type
NANO 04 VD
Three phase
Working temperature
NANO 04 VD
-5 ÷ +50 °C
Storage temperature
NANO 04 VD
-10 ÷ +70°C
Relative ambient humidity
NANO 04 VD
30% - 90% RH without condensate
Door lock main switch
NANO 04 VD
16 A
Compressor protection
NANO 04 VD
Thermal relay
General protection
NANO 04 VD
Fuses
Control
NANO 04 VD
PEGO Thermoregulator (Expert Nano 4CK)
Alarm signals
NANO 04 VD
Display + Buzzer
Defrosting
NANO 04 VD
Electrical
Clock (RTC)
NANO 04 VD
Present
Ambient probe
NANO 04 VD
NTC 10 kΩ
Evaporator probe
NANO 04 VD
NTC 10 kΩ
Door switch
NANO 04 VD
Present
High/low pressure switch
NANO 04 VD
Present
Kriwan® connection
NANO 04 VD
Present
Compressor
NANO 04 VD
1800W (0,5 ÷ 2,5 HP)
Defrosting
NANO 04 VD
1200W (1 PH)
Evaporator fans
NANO 04 VD
250W (1 PH)
Condenser fans output 1
NANO 04 VD
800W (1 PH)
Solenoid valve
NANO 04 VD
Present
Compressor oil heater
NANO 04 VD
Present
Room light
NANO 04 VD
Present
Supervision
NANO 04 VD
TeleNet / Modbus-RTU
Technical Characteristics
Inputs
Outputs
Dimensions and Diagram
Available Versions
NANO 04 VD
Product Code
10004VDX05
10004VDX06
10004VDX07
10004VDX08
10004VDX10
Compressor
Product Code
10004VDX05
10004VDX05
1.8 - 2.5 A
Product Code
10004VDX06
10004VDX06
2.8 - 4.0 A
Product Code
10004VDX07
10004VDX07
4.5 - 6.3 A
Product Code
10004VDX08
10004VDX08
5.5 - 8.0 A
Product Code
10004VDX10
10004VDX10
3.5 - 5.0 A
Evaporator fan
Product Code
10004VDX05
10004VDX05
0,25 kW
Product Code
10004VDX06
10004VDX06
0,25 kW
Product Code
10004VDX07
10004VDX07
0,25 kW
Product Code
10004VDX08
10004VDX08
0,25 kW
Product Code
10004VDX10
10004VDX10
0,25 kW
Defrosting
Product Code
10004VDX05
10004VDX05
1,2 kW
Product Code
10004VDX06
10004VDX06
1,2 kW
Product Code
10004VDX07
10004VDX07
1,2 kW
Product Code
10004VDX08
10004VDX08
1,2 kW
Product Code
10004VDX10
10004VDX10
1,2 kW
Electronic expansion valve
Product Code
10004VDX05
10004VDX05
No
Product Code
10004VDX06
10004VDX06
No
Product Code
10004VDX07
10004VDX07
No
Product Code
10004VDX08
10004VDX08
No
Product Code
10004VDX10
10004VDX10
No
Man in cold-room alarm
Product Code
10004VDX05
10004VDX05
No
Product Code
10004VDX06
10004VDX06
No
Product Code
10004VDX07
10004VDX07
No
Product Code
10004VDX08
10004VDX08
No
Product Code
10004VDX10
10004VDX10
No
Complete cold room management
Product Code
10004VDX05
10004VDX05
Yes
Product Code
10004VDX06
10004VDX06
Yes
Product Code
10004VDX07
10004VDX07
Yes
Product Code
10004VDX08
10004VDX08
Yes
Product Code
10004VDX10
10004VDX10
Yes
Condensing unit management
Product Code
10004VDX05
10004VDX05
No
Product Code
10004VDX06
10004VDX06
No
Product Code
10004VDX07
10004VDX07
No
Product Code
10004VDX08
10004VDX08
No
Product Code
10004VDX10
10004VDX10
No
Temperature/Humidity Management
Product Code
10004VDX05
10004VDX05
No
Product Code
10004VDX06
10004VDX06
No
Product Code
10004VDX07
10004VDX07
No
Product Code
10004VDX08
10004VDX08
No
Product Code
10004VDX10
10004VDX10
No
Evaporating unit management
Product Code
10004VDX05
10004VDX05
No
Product Code
10004VDX06
10004VDX06
No
Product Code
10004VDX07
10004VDX07
No
Product Code
10004VDX08
10004VDX08
No
Product Code
10004VDX10
10004VDX10
No
Double system management
Product Code
10004VDX05
10004VDX05
No
Product Code
10004VDX06
10004VDX06
No
Product Code
10004VDX07
10004VDX07
No
Product Code
10004VDX08
10004VDX08
No
Product Code
10004VDX10
10004VDX10
No
Valve management electronic on/off
Product Code
10004VDX05
10004VDX05
No
Product Code
10004VDX06
10004VDX06
No
Product Code
10004VDX07
10004VDX07
No
Product Code
10004VDX08
10004VDX08
No
Product Code
10004VDX10
10004VDX10
No
Valve management Stepper electronics
Product Code
10004VDX05
10004VDX05
No
Product Code
10004VDX06
10004VDX06
No
Product Code
10004VDX07
10004VDX07
No
Product Code
10004VDX08
10004VDX08
No
Product Code
10004VDX10
10004VDX10
No
Double evaporator management
Product Code
10004VDX05
10004VDX05
No
Product Code
10004VDX06
10004VDX06
No
Product Code
10004VDX07
10004VDX07
No
Product Code
10004VDX08
10004VDX08
No
Product Code
10004VDX10
10004VDX10
No
Datalogger
Product Code
10004VDX05
10004VDX05
No
Product Code
10004VDX06
10004VDX06
No
Product Code
10004VDX07
10004VDX07
No
Product Code
10004VDX08
10004VDX08
No
Product Code
10004VDX10
10004VDX10
No