PRODUCTS | ELECTRICAL BOARDS
NANO 15/19.5 U VD
A LINE OF POWER AND ELECTRONIC CONTROL BOARDS FOR CONTROL OF THE EVAPORATING UNIT ONLY
A line of power and electronic control boards for control of the three-phase evaporating unit only where devices are served by a compressor rack. You can control the room light and the stand-by system using the buttons on the thermostat. Integrated PEGO thermo-regulator controls cold, ventilation, defrosting and light calls. The unit also controls the door switch, which automatically turns on the room light, fan shutdown and cold call shutdown.
Applications
-
Control of evaporating unit only with electrical defrost up to 19.5 kW.
Main characteristics
- Designed to provide an immediate start-up and easy maintenance.
- Enabling for motor condenser unit, defrosting elements, evaporator fans, solenoid valve, room light, door element and all standard-compliant electrical safeguards.
- Compact, self-extinguishing ABS housing with IP55 protection rating and circuit breaker on front of panel.
- Integrated PEGO thermo-regulator (Expert Nano 4CK).
- System status indicated by display.
- Key operated ON/OFF.
- Cold room light ON/OFF switch with key or by means of door switch.
- Key operated manual START/STOP defrosting.
- Clock for programmed defrost (RTC).
- Configurable multifunction output, alternative to the light output.
- RS485 serial connection with Modbus-RTU or Telenet protocol.
Options
- Installation of magnetothermic circuit breakers instead of fuses.
Properties
NANO 15 U VD
NANO 19.5 U VD
Dimension
NANO 15 U VD
350x450x160 mm
NANO 19.5 U VD
350x450x160 mm
Weight
NANO 15 U VD
6kg
NANO 19.5 U VD
7kg
Front protection rating
NANO 15 U VD
IP 55
NANO 19.5 U VD
IP 55
Power supply
NANO 15 U VD
400 VAC ±10% 50/60 Hz
NANO 19.5 U VD
400 VAC ±10% 50/60 Hz
Status indicator
NANO 15 U VD
Display
NANO 19.5 U VD
Display
Load type
NANO 15 U VD
Three phase
NANO 19.5 U VD
Three phase
Working temperature
NANO 15 U VD
-5 ÷ +50 °C
NANO 19.5 U VD
-5 ÷ +50 °C
Storage temperature
NANO 15 U VD
-10 ÷ +70 °C
NANO 19.5 U VD
-10 ÷ +70°C
Relative ambient humidity
NANO 15 U VD
30% - 90% RH without condensate
NANO 19.5 U VD
30% - 90% RH without condensate
Door lock main switch
NANO 15 U VD
32 A
NANO 19.5 U VD
32 A
General protection
NANO 15 U VD
Fuses
NANO 19.5 U VD
Fuses
Control
NANO 15 U VD
PEGO Thermoregulator (Expert Nano 4CK)
NANO 19.5 U VD
PEGO Thermoregulator (Expert Nano 4CK)
Alarm signals
NANO 15 U VD
Display + Buzzer
NANO 19.5 U VD
Display + Buzzer
Defrosting
NANO 15 U VD
Electrical
NANO 19.5 U VD
Electrical
Insulation transformer
NANO 15 U VD
Present
NANO 19.5 U VD
Present
Clock (RTC)
NANO 15 U VD
Present
NANO 19.5 U VD
Present
Ambient probe
NANO 15 U VD
NTC 10 kΩ
NANO 19.5 U VD
NTC 10 kΩ
Evaporator probe
NANO 15 U VD
NTC 10 kΩ
NANO 19.5 U VD
NTC 10 kΩ
Door switch
NANO 15 U VD
Present
NANO 19.5 U VD
Present
Defrosting
NANO 15 U VD
15000W (5000W x 3, AC1)
NANO 19.5 U VD
19500W (6500W x 3, AC1)
Evaporator fans
NANO 15 U VD
2000W x 2 (3 PH)
NANO 19.5 U VD
2000W x 2 (3 PH)
Solenoid valve
NANO 15 U VD
Present
NANO 19.5 U VD
Present
Enable condensing unit
NANO 15 U VD
Present
NANO 19.5 U VD
Present
Room light
NANO 15 U VD
Present
NANO 19.5 U VD
Present
Supervision
NANO 15 U VD
TeleNet / Modbus-RTU
NANO 19.5 U VD
TeleNet / Modbus-RTU
Technical Characteristics
Inputs
Outputs
Dimensions and Diagram
Available Versions
NANO 15 U VD
NANO 19.5 U VD
Product Code
100U150X01
Product Code
100U195X01
Compressor
Product Code
100U150X01
100U150X01
No
Evaporator fan
Product Code
100U150X01
100U150X01
2,0 kW
Defrosting
Product Code
100U150X01
100U150X01
15,0 kw
Electronic expansion valve
Product Code
100U150X01
100U150X01
No
Man in cold-room alarm
Product Code
100U150X01
100U150X01
No
Complete cold room management
Product Code
100U150X01
100U150X01
No
Condensing unit management
Product Code
100U150X01
100U150X01
No
Temperature/Humidity Management
Product Code
100U150X01
100U150X01
No
Evaporating unit management
Product Code
100U150X01
100U150X01
Yes
Double system management
Product Code
100U150X01
100U150X01
No
Valve management electronic on/off
Product Code
100U150X01
100U150X01
No
Valve management Stepper electronics
Product Code
100U150X01
100U150X01
No
Double evaporator management
Product Code
100U150X01
100U150X01
No
Datalogger
Product Code
100U150X01
100U150X01
No
Compressor
Product Code
100U195X01
100U195X01
No
Evaporator fan
Product Code
100U195X01
100U195X01
2,0 kW
Defrosting
Product Code
100U195X01
100U195X01
19,5 kW
Electronic expansion valve
Product Code
100U195X01
100U195X01
No
Man in cold-room alarm
Product Code
100U195X01
100U195X01
No
Complete cold room management
Product Code
100U195X01
100U195X01
No
Condensing unit management
Product Code
100U195X01
100U195X01
No
Temperature/Humidity Management
Product Code
100U195X01
100U195X01
No
Evaporating unit management
Product Code
100U195X01
100U195X01
Yes
Double system management
Product Code
100U195X01
100U195X01
No
Valve management electronic on/off
Product Code
100U195X01
100U195X01
No
Valve management Stepper electronics
Product Code
100U195X01
100U195X01
No
Double evaporator management
Product Code
100U195X01
100U195X01
No
Datalogger
Product Code
100U195X01
100U195X01
No